{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D65004BW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D65004BW","canonicalUrl":"https://aoctrl.com/schneider/LP1D65004BW","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D65004BW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LP1D65004BW, obsolete 4-pole contactor, 80 A AC-1 at 440 V, 24 V DC coil.","salesMarkdown":"The Schneider Electric LP1D65004BW is a 4-pole contactor from the TeSys Deca range, rated for resistive loads at 80 A AC-1 at 440 V, with a 24 V DC coil. It's a panel-mount component used to switch power circuits in industrial control cabinets, typically for heater banks, lighting, or other resistive loads where the AC-1 rating governs continuous current. The AC-1 rating of 80 A at 440 V defines its capacity for resistive loads — this is the current it can carry continuously without overheating. For motor duty (AC-3), the contactor is also rated, but the specific current value isn't listed here; the AC-1 figure is the one to match against your load's steady-state draw. The 24 V DC coil means it pulls in cleanly on a standard 24 VDC control supply, with a dropout threshold typically around 18 V. The 4-pole configuration (4P) allows switching of three phases plus neutral, or four independent resistive circuits. The contactor carries approvals under IEC 60947-4-1, EN 60947-4-1, VDE 0660, BS 5424, and NF C 63-110, which cover its use in industrial control panels across Europe and other IEC-adopting regions. Flame retardance is V1 per UL 94, and fire resistance to 850 °C per IEC 60695-2-1, so it meets the thermal runaway containment requirements for enclosed panel installations. Storage range extends from -60 to 80 °C. The IP2X degree of protection (per IEC 60529 and VDE 0106) means it's finger-safe but not sealed against moisture — mount it inside a panel with appropriate enclosure rating. ## Integration Notes Mounts on a rail or plate (mounting support: Rail Plate). Dimensions are 85 mm wide, 127 mm high, 182 mm deep — check your panel's DIN-rail spacing and enclosure depth before committing.","metaTitle":"Schneider TeSys LP1D65004BW Contactor, 4P, 80A AC-1, 24VDC C","metaDescription":"Obsolete Schneider TeSys Deca LP1D65004BW contactor, 4 poles, 80A AC-1 at 440V, 24VDC coil. Sourced to order against RFQ. Complies with IEC 60947, VDE 0660.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"182 mm","Width":"85 mm","Height":"127 mm","Standards":"VDE 0660 IEC 60947-1 BS 5424 EN 60947-4-1 IEC 60947-4-1 EN 60947-1 NF C 63-110 JEM 1038","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting support":"Rail Plate","Non-overlap time":"1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts","Range of product":"TeSys Deca","Device short name":"LP1D","Poles description":"4P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1 AC-3 AC-3e AC-4","Contactor application":"Resistive load","Mechanical robustness":"Shocks contactor opened (10 Gn) Shocks contactor closed (15 gn) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)","IP degree of protection":"IP2X conforming to IEC 60529 IP2X conforming to VDE 0106","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-60...80 °C storage -40...60 °C operation 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/6effc660ef4121cecdf8913042ded18a.pdf","sourceUrl":"https://www.se.com/au/en/product/LP1D65004BW/contactor-tesys-lp1d-4-poles-ac1-440v-80-a-coil-24-v-dc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1D65004BW/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a 4-pole contactor rated 80 A AC-1 at 440 V for resistive loads, with a 24 V DC coil. It complies with IEC 60947-4-1, VDE 0660, and other standards. Operating temperature is -40 to 60 °C, and it mounts on a rail or plate."},{"question":"What compliance documentation does Schneider provide for this part?","answer":"The contactor carries approvals under IEC 60947-4-1, EN 60947-4-1, VDE 0660, BS 5424, NF C 63-110, and JEM 1038. It has V1 flame retardance per UL 94 and 850 °C fire resistance per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D65004BW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D65004BW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}