{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D65004ND","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D65004ND","canonicalUrl":"https://aoctrl.com/schneider/LP1D65004ND","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D65004ND","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca series, LP1D65004ND, 4-pole contactor, AC-1 440V 80 A, coil 60 V DC, IP2X, active production.","salesMarkdown":"The LP1D65004ND is a 4-pole contactor from the TeSys Deca range, rated for AC-1 resistive loads at 80 A and 440 V, with a 60 V DC coil. It's built to switch motor loads in control panels and industrial machinery, with utilisation categories covering AC-1, AC-3, AC-3e, and AC-4 duty. The coil pulls 60 V DC, so you'll need a DC supply on the control side — common in 48 V or 60 V battery-backed systems or when you've got a DC bus running through the panel. The 4-pole configuration (3 poles plus one auxiliary or a fourth power pole) gives you flexibility for two-speed motors or switching the neutral in a single-phase load. The headline AC-1 rating of 80 A at 440 V is for resistive loads — think heaters, lighting banks. But the AC-3 and AC-4 ratings are what matter for motor switching: AC-3 covers starting and stopping a squirrel-cage motor under full load, while AC-4 handles inching and plugging. The actual AC-3 current rating isn't listed here, so when you're sizing this for a motor, you'll want to check the TeSys Deca selection table — the AC-1 number is the ceiling for resistive duty, not the motor rating. The contactor is rated for operation from -40 to 60 °C ambient, with derating up to 70 °C. That's a wide thermal window — it'll survive a hot summer in a non-air-conditioned plant room. Storage range goes from -60 to 80 °C, which covers shipping through a northern winter or sitting in a warehouse in the desert. Altitude derating kicks in above 3000 m, so if your site is at 3500 m in the Andes, you'll need to reduce the current rating. IP2X protection means it's finger-safe — you can't poke a screwdriver into the live parts — but it's not sealed against dust or water. This is a panel-mount part, so it goes inside an enclosure, not out in the weather. This contactor carries compliance with IEC 60947-4-1 (the main standard for contactors and motor-starters), EN 60947-1, BS 5424, VDE 0660, and JEM 1038. That's the full set of European and international standards you'd expect for a machine going into a CE-marked panel. The V1 flame retardance per UL 94 and 850 °C glow-wire resistance per IEC 60695-2-1 mean the plastic body won't propagate a fire if something goes wrong inside the panel.","metaTitle":"Schneider TeSys Deca LP1D65004ND Contactor, 4P, 80A AC-1, 60","metaDescription":"Active-production TeSys Deca contactor, 4 poles, AC-1 440V 80 A, coil 60 V DC. Complies with IEC 60947-4-1, EN 60947-1. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"182 mm","Width":"85 mm","title":"LP1D65004ND","Height":"127 mm","Standards":"EN 60947-1 VDE 0660 NF C 63-110 JEM 1038 IEC 60947-4-1 BS 5424 EN 60947-4-1 IEC 60947-1","description":"contactor - TeSys LP1-D - 4 poles - AC-1 440V 80 A - coil 60 V DC","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting support":"Rail Plate","Non-overlap time":"1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts","Range of product":"TeSys Deca","Device short name":"LP1D","Poles description":"4P","Operating altitude":"3000 m without derating","Protective treatment":"TH (pollution degree 3) conforming to IEC 60068","Utilisation category":"AC-1 AC-3 AC-3e AC-4","Contactor application":"Resistive load","Mechanical robustness":"Shocks contactor opened (10 Gn) Shocks contactor closed (15 gn) Vibrations contactor opened (2 Gn, 5...300 Hz) Vibrations contactor closed (4 Gn, 5...300 Hz)","IP degree of protection":"IP2X conforming to IEC 60529 IP2X conforming to VDE 0106","Product or component type":"Contactor","[Ue] rated operational voltage":"Power circuit: 10 MOhm for control circuit","Permissible ambient air temperature around the device":"-60...80 °C storage -40...60 °C operation 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/456ef7745cba75e4c2150f57504dd2e2.pdf","sourceUrl":"https://www.se.com/au/en/product/LP1D65004ND/contactor-tesys-lp1d-4-poles-ac1-440v-80-a-coil-60-v-dc/"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It's a 4-pole contactor rated AC-1 80 A at 440 V with a 60 V DC coil. Utilisation categories include AC-1, AC-3, AC-3e, and AC-4. Ambient operating range is -40 to 60 °C, with altitude derating above 3000 m."},{"question":"What standards does this contactor comply with?","answer":"It complies with IEC 60947-4-1, EN 60947-1, BS 5424, VDE 0660, JEM 1038, and NF C 63-110. It also meets UL 94 V1 flame retardance and 850 °C glow-wire resistance."},{"question":"What is the mounting method for this part?","answer":"It mounts on a rail or plate — standard DIN-rail or panel-mount. It's designed for inside an enclosure, not standalone outdoor use."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D65004ND","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D65004ND when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}