{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D65008BD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D65008BD","canonicalUrl":"https://aoctrl.com/schneider/LP1D65008BD","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D65008BD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider TeSys Deca LP1D65008BD, 4-pole contactor, 80 A AC-1, DC coil with integrated bidirectional peak limiting diode suppressor.","salesMarkdown":"The Schneider LP1D65008BD is a TeSys Deca contactor rated for 80 A in AC-1 resistive duty, with 4 poles and a DC coil that includes a built-in bidirectional peak limiting diode suppressor — no external flyback diode needed. Mechanical durability hits 10 Mcycles; electrical durability at rated load is 1.5 Mcycles. AC-1 utilisation category limits this contactor to resistive loads only — not for motor starting or inductive switching. The 80 A rating is continuous at 440 V. If your panel runs heating elements, lighting banks, or transformer primaries that stay within resistive inrush, this part is on-spec. The 4-pole frame (2 NO + 2 NC) suits three-phase plus neutral or dual independent load circuits. Coil suppression is already inside the contactor — the bidirectional peak limiting diode cuts EMI and protects the DC driver circuit. The control circuit operates on DC only; no AC coil variant here. Rated making and breaking capacity is 1000 A at 440 V for the power circuit, per IEC 60947. ## Mounting and wiring note Mounts on plate or rail. Screw-clamp terminals on power and control circuits; torque spec is 70.8 lbf·in (8 N·m) for power conductors up to 25 mm² flexible with ferrule, and 15.05 lbf·in (1.7 N·m) for control wiring. Accepts solid or stranded copper. The IP20 front face keeps fingers out but doesn't seal against washdown. Pollution degree 3 environment — okay for most control panels unless exposure to conductive dust is extreme.","metaTitle":"Schneider LP1D65008BD TeSys Deca 4P Contactor","metaDescription":"80 A AC-1 contactor, 4 poles, DC coil with integrated diode suppressor. Active production, UL/CSA/IEC listed. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"7.2 in (182 mm)","Range":"TeSys","Width":"3.3 in (85 mm)","Height":"5 in (127 mm)","Category":"US10I1222358","Standards":"CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 60947-4-1","Time constant":"75 ms","Operating time":"4...19 ms opening 12...26 ms closing","Coil technology":"Built-in bidirectional peak limiting diode suppressor","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting Support":"Plate Rail","Pollution degree":"3","Protective cover":"With","Range of Product":"TeSys Deca","Average impedance":"1.5 mOhm - Ith 80 A 50 Hz for power circuit","Device short name":"LP1D","Inrush power in W":"22 W 68 °F (20 °C))","Poles description":"4P","Tightening torque":"Power circuit 70.8 lbf.in (8 N.m) screw clamp terminals 0.04...0.05 in² (25...35 mm²) hexagonal 0.2 in (4 mm) Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 44.3 lbf.in (5 N.m) screw clamp terminals 0.002...0.04 in² (1...25 mm²) hexagonal 0.2 in (4 mm) Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals pozidriv No 2","Compatibility code":"LP1D","Operating altitude":"0...9842.52 ft (0...3000 m)","Control circuit type":"DC DC standard","Overvoltage category":"III","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"1.5 Mcycles 80 A AC-1 <= 440 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Shocks contactor open 8 Gn for 11 ms) Shocks contactor closed 10 Gn for 11 ms) Vibrations contactor opened 2 Gn, 5...300 Hz) Vibrations contactor closed 3 Gn, 5...300 Hz)","Nbr. of units in pkg.":"1","Associated fuse rating":"125 A gG at 125 A gG at <= 690 V coordination type 2 for power circuit","Maximum operating rate":"3600 cyc/h at 60 °C","Connections - terminals":"Power circuit: screw clamp terminals 1 0.004...0.04 in² (2.5...25 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 0.004...0.02 in² (2.5...16 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 0.004...0.04 in² (2.5...25 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 0.004...0.02 in² (2.5...10 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 0.004...0.04 in² (2.5...25 mm²) - cable stiffness: solid Power circuit: screw clamp terminals 2 0.004...0.02 in² (2.5...16 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"1000 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"1000 A at 440 V for power circuit conforming to IEC 60947","Power dissipation per pole":"9.6 W AC-1","[Uc] control circuit voltage":"24 V DC","[Ui] rated insulation voltage":"Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL","Control circuit voltage limits":"0.1...0.3 Uc (-40...131 °F (-40...55 °C)):drop-out DC 0.85...1.1 Uc (-40...131 °F (-40...55 °C)):operational DC","Hold-in power consumption in W":"22 W 68 °F (20 °C)","[Ie] rated operational current":"80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit <= 1000 V AC 25...400 Hz","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947","[Icw] rated short-time withstand current":"110 A 104 °F (40 °C) - 10 min for power circuit 260 A 104 °F (40 °C) - 1 min for power circuit 520 A 104 °F (40 °C) - 10 s for power circuit 900 A 104 °F (40 °C) - 1 s for power circuit","[Ith] conventional free air thermal current":"80 A (at 140 °F (60 °C)) for power circuit","Permissible ambient air temperature around the device":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$194.31","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a416145f3ac57dc4bb1291409e0bd38b.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1D65008BD/alternatives.json"},"ai":{"faq":[{"question":"What compliance standards does the LP1D65008BD meet?","answer":"It is listed to UL 60947-4-1, CSA C22.2 No 14, IEC 60947-4-1, and IEC 60947-5-1. Fire resistance is rated at 850 °C per IEC 60695-2-1, and flame retardance is V1 per UL 94."},{"question":"What is the exact depth of the LP1D65008BD?","answer":"The depth is 7.2 in (182 mm)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D65008BD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D65008BD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}