{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D65008FW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D65008FW","canonicalUrl":"https://aoctrl.com/schneider/LP1D65008FW","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D65008FW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LP1D65008FW 4-pole contactor, 80 A AC-1, 2 NO + 2 NC, DC wide-range coil, screw clamp terminals, IP20 front face.","salesMarkdown":"## 80 A AC-1 resistive load contactor for panel builders The LP1D65008FW: That 80 A figure governs the continuous current through the power poles when switching heaters, ovens, or lighting banks — not motor starting, which would fall under AC-3 and be lower. The 4-pole configuration with 2 NO + 2 NC contacts gives you the flexibility to switch two independent load circuits or use the NC pair for interlocking or status feedback. The DC wide-range control coil includes a built-in bidirectional peak limiting diode suppressor, so you don't need an external flyback diode across the coil — one less component on the panel layout. Power dissipation per pole runs 9.6 W at AC-1 rating, which adds up to 38.4 W total through the contactor body; account for that thermal load when spacing devices in the enclosure. ## Making and breaking capacity for fault coordination The associated fuse recommendation is 125 A gG at up to 690 V for type 2 coordination, which keeps the contactor serviceable after a short circuit rather than requiring replacement. Electrical durability is 1.4 million cycles at 80 A AC-1, 440 V. Mechanical durability stretches to 6 million cycles — the gap between those numbers tells you the contact wear under load is the life limiter. For applications that cycle infrequently (like oven contactors), the mechanical life is essentially infinite. ## Safety reliability and standards compliance Safety reliability is quantified with B10d values: 1,369,863 cycles under nominal load and 20,000,000 cycles under mechanical load per EN/ISO 13849-1. That B10d at nominal load is the figure to plug into your safety circuit PFHd calculation — the higher mechanical B10d applies only when switching no current. The contactor carries approvals to CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, and UL 508. Flame retardance is V1 per UL 94; fire resistance tested to 850 °C per IEC 60695-2-1. ## Panel fit and termination Dimensions are 7.2 in deep by 3.3 in wide by 5 in tall (182 x 85 x 127 mm). The 4-pole width is the same as a 3-pole TeSys Deca contactor — the extra pole fits within the same footprint. Mounting is rail or plate, which covers both DIN rail and direct panel screw-down. Tightening torque is 70.8 lbf·in (8 N·m) for power connections — use a torque screwdriver to avoid terminal damage. Control circuit terminals are smaller: 1.7 N·m for up to 4 mm² wire. Front face is IP20 per IEC 60529, which is standard for enclosed panel mount — finger-safe from the front but not sealed against dust ingress. The operating altitude range is 0 to 3000 m without derating.","metaTitle":"Schneider Electric TeSys Deca LP1D65008FW Contactor, 4P","metaDescription":"Schneider Electric TeSys Deca LP1D65008FW 4-pole contactor, 80 A AC-1, 2 NO + 2 NC, DC wide-range coil. UL/CSA/IEC listed, active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"7.2 in (182 mm)","Range":"TeSys","Width":"3.3 in (85 mm)","Height":"5 in (127 mm)","Category":"22357-CTR,TESYS D,OPEN,40-65A AC","Standards":"CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508","Time constant":"75 ms","Operating time":"4...19 ms opening 12...26 ms closing","Coil technology":"Built-in bidirectional peak limiting diode suppressor","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting Support":"Rail Plate","Pollution degree":"3","Protective cover":"Without","Range of Product":"TeSys Deca","Average impedance":"1.5 mOhm - Ith 80 A 50 Hz for power circuit","Device short name":"LP1D","Inrush power in W":"22 W 68 °F (20 °C))","Poles description":"4P","Tightening torque":"Power circuit 70.8 lbf.in (8 N.m) screw clamp terminals 0.04...0.05 in² (25...35 mm²) hexagonal 0.2 in (4 mm) Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals flat Ø 6 mm Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Philips No 2 Power circuit 44.3 lbf.in (5 N.m) screw clamp terminals 0.002...0.04 in² (1...25 mm²) hexagonal 0.2 in (4 mm)","Compatibility code":"LP1D","Operating altitude":"0...9842.52 ft (0...3000 m)","Control circuit type":"DC wide range","Overvoltage category":"III","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"1.4 Mcycles 80 A AC-1 <= 440 V","Mechanical durability":"6 Mcycles","Mechanical robustness":"Shocks contactor open 8 Gn for 11 ms) Shocks contactor closed 10 Gn for 11 ms) Vibrations contactor opened 2 Gn, 5...300 Hz) Vibrations contactor closed 3 Gn, 5...300 Hz)","Nbr. of units in pkg.":"1","Associated fuse rating":"125 A gG at 125 A gG at <= 690 V coordination type 2 for power circuit","Connections - terminals":"Power circuit: screw clamp terminals 1 0.002...0.05 in² (1...35 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 2 0.002...0.04 in² (1...25 mm²) - cable stiffness: flexible without cable end Power circuit: screw clamp terminals 1 0.002...0.05 in² (1...35 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 2 0.002...0.04 in² (1...25 mm²) - cable stiffness: flexible with cable end Power circuit: screw clamp terminals 1 0.002...0.05 in² (1...35 mm²) - cable stiffness: solid Power circuit: screw clamp terminals 2 0.002...0.04 in² (1...25 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"1000 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"1000 A at 440 V for power circuit conforming to IEC 60947","Power dissipation per pole":"9.6 W AC-1","[Uc] control circuit voltage":"110 V DC","[Ui] rated insulation voltage":"Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL","Control circuit voltage limits":"0.1...0.3 Uc (-40...158 °F (-40...70 °C)):drop-out DC 0.75...1.2 Uc (-40...131 °F (-40...55 °C)):operational DC 1...1.2 Uc (131...158 °F (55...70 °C)):operational DC","Hold-in power consumption in W":"22 W 68 °F (20 °C)","[Ie] rated operational current":"80 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit Power circuit <= 300 V DC","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947","[Icw] rated short-time withstand current":"110 A 104 °F (40 °C) - 10 min for power circuit 260 A 104 °F (40 °C) - 1 min for power circuit 520 A 104 °F (40 °C) - 10 s for power circuit 900 A 104 °F (40 °C) - 1 s for power circuit","[Ith] conventional free air thermal current":"80 A (at 140 °F (60 °C)) for power circuit","Permissible ambient air temperature around the device":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$295.91","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/vn/en/product/LP1D65008FW/tesys-d-contactor-4p2-no-+-2-nc-ac1-440-v-80-a-110-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1D65008FW/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does the LP1D65008FW carry?","answer":"The contactor is certified to CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, and UL 508. Flame retardance is V1 per UL 94, and fire resistance is tested to 850 °C per IEC 60695-2-1."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D65008FW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D65008FW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}