{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D800046CW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D800046CW","canonicalUrl":"https://aoctrl.com/schneider/LP1D800046CW","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D800046CW","rawCanonicalId":null},"summary":{"shortDescription":"Contactor, TeSys Deca, 4P (4NO), AC-1 <=440V 125 A, 36 V DC wide range coil, ring-lug terminals","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"7.1 in (181 mm)","Range":"TeSys","Width":"3.8 in (96 mm)","Height":"5 in (127 mm)","Category":"22359-CTR,TESYS D,OPEN,80-150A AC&DC","Standards":"CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508","Time constant":"75 ms","Operating time":"6...20 ms opening 20...35 ms closing","Coil technology":"Without built-in suppressor module","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting Support":"Rail Plate","Pollution degree":"3","Protective cover":"Without","Range of Product":"TeSys Deca","Average impedance":"0.8 mOhm - Ith 125 A 50 Hz for power circuit","Device short name":"LP1D","Inrush power in W":"22 W 68 °F (20 °C))","Poles description":"4P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) lugs-ring terminals flat Ø 6 mm M3.5 Control circuit 10.6 lbf.in (1.2 N.m) lugs-ring terminals Philips No 2 M3.5 Power circuit 106.2 lbf.in (12 N.m) lugs-ring terminals hexagonal 0.4 in (10 mm) M6 Power circuit 106.2 lbf.in (12 N.m) lugs-ring terminals flat Ø 8 mm M6 Power circuit 106.2 lbf.in (12 N.m) bars flat Ø 8 mm M6 Power circuit 106.2 lbf.in (12 N.m) bars hexagonal 0.4 in (10 mm) M6","Compatibility code":"LP1D","Operating altitude":"0...9842.52 ft (0...3000 m)","Control circuit type":"DC wide range","Overvoltage category":"III","Utilisation category":"AC-1 AC-3 AC-3e AC-4","Contactor application":"Resistive load","Electrical durability":"0.8 Mcycles 125 A AC-1 <= 440 V","Mechanical durability":"4 Mcycles","Mechanical robustness":"Vibrations contactor open 2 Gn, 5...300 Hz) Vibrations contactor closed 3 Gn, 5...300 Hz) Shocks contactor open 8 Gn for 11 ms) Shocks contactor closed 10 Gn for 11 ms)","Nbr. of units in pkg.":"1","Associated fuse rating":"200 A gG at 160 A gG at <= 690 V coordination type 2 for power circuit","Maximum operating rate":"3600 cyc/h 140 °F (60 °C)","Connections - terminals":"Control circuit: lugs-ring terminals - external diameter: 0.3 in (8 mm) Power circuit: lugs-ring terminals - external diameter: 0.7 in (17 mm) Power circuit: bars 1 - busbar cross section: 3 x 16 mm","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"4 NO","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Power dissipation per pole":"12.5 W AC-1","[Uc] control circuit voltage":"36 V DC","[Ui] rated insulation voltage":"Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1","Control circuit voltage limits":"0.1...0.3 Uc (-40...158 °F (-40...70 °C)):drop-out DC 0.75...1.2 Uc (-40...131 °F (-40...55 °C)):operational DC 1...1.2 Uc (131...158 °F (55...70 °C)):operational DC","Hold-in power consumption in W":"22 W 68 °F (20 °C)","[Ie] rated operational current":"125 A (at <140 °F (60 °C)) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit Power circuit <= 300 V DC","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947","[Icw] rated short-time withstand current":"135 A 104 °F (40 °C) - 10 min for power circuit 320 A 104 °F (40 °C) - 1 min for power circuit 640 A 104 °F (40 °C) - 10 s for power circuit 990 A 104 °F (40 °C) - 1 s for power circuit","[Ith] conventional free air thermal current":"125 A (at 140 °F (60 °C)) for power circuit","Permissible ambient air temperature around the device":"-76...176 °F (-60...80 °C) storage -40...140 °F (-40...60 °C) operation 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/761f97511159ef53199a16a7aa33d533.pdf","sourceUrl":"https://www.se.com/us/en/product/LP1D800046CW/contactor-tesys-deca-4p-4no-ac1-440v-125-a-36-v-dc-wide-range-coil-ringlug-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1D800046CW/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D800046CW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D800046CW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}