{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D80004DW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D80004DW","canonicalUrl":"https://aoctrl.com/schneider/LP1D80004DW","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D80004DW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LP1D80004DW, 4-pole contactor, 96 V DC wide-range coil, 125 A AC-1, 4 NO power poles.","salesMarkdown":"The Schneider Electric TeSys Deca LP1D80004DW is a 4-pole contactor with a 96 V DC wide-range coil, rated for utilisation categories AC-1, AC-3, AC-3e, and AC-4. The 4 NO power poles handle resistive loads (AC-1) and motor loads (AC-3/AC-3e/AC-4) up to the rated breaking and making capacity of 1100 A at 440 V per IEC 60947. Electrical durability is 0.8 Mcycles at 125 A AC-1, ≤440 V; mechanical durability is 4 Mcycles. Approvals include CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, and UL 508. ## Integration notes The power circuit uses a connector accepting 4–50 mm² flexible or solid cable; control circuit screw clamp terminals accept 1–4 mm². Tightening torque is 12 N·m for power connections and 1.2 N·m for control wiring. The coil draws 22 W inrush at 20 °C and has a time constant of 75 ms. Operating time is 6–20 ms opening, 20–35 ms closing. No built-in suppressor module — plan external diode or RC snubber for DC coil suppression. ## Standards & environment Fire resistance is 850 °C per IEC 60695-2-1; flame retardance is V1 per UL 94. The contactor withstands vibrations of 2 Gn (open) and 3 Gn (closed) at 5–300 Hz, and shocks of 8 Gn (open) and 10 Gn (closed) for 11 ms. Associated fuse rating for type 2 coordination on the power circuit is 200 A gG at ≤690 V. Maximum operating rate is 3600 cycles per hour at 60 °C.","metaTitle":"TeSys Deca LP1D80004DW 4-pole contactor, 96 V DC coil, 125 A","metaDescription":"Schneider Electric TeSys Deca LP1D80004DW 4-pole contactor, 96 V DC coil, rated 125 A AC-1. UL/CSA/IEC certified, current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"181 mm","Range":"TeSys","Width":"96 mm","title":"LP1D80004DW","Height":"127 mm","Standards":"CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508","description":"Contactor, TeSys Deca,4P(4 NO), AC-1, <= 440 V 125 A - 96 V DC coil","Time constant":"75 ms","Operating time":"6...20 ms opening 20...35 ms closing","Coil technology":"Without built-in suppressor module","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting support":"Plate Rail","Pollution degree":"3","Protective cover":"Without","Range of product":"TeSys Deca","Average impedance":"0.8 mOhm - Ith 125 A 50 Hz for power circuit","Device short name":"LP1D","Inrush power in W":"22 W (at 20 °C)","Poles description":"4P","Tightening torque":"Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 Power circuit: 12 N.m - on connector - with screwdriver flat Ø 6 to Ø 8 mm Power circuit: 12 N.m - on connector hexagonal screw head 4 mm","Compatibility code":"LP1D","Operating altitude":"0...3000 m","Control circuit type":"DC wide range","Overvoltage category":"III","Utilisation category":"AC-1 AC-3 AC-3e AC-4","Contactor application":"Resistive load","Electrical durability":"0.8 Mcycles 125 A AC-1 at Ue <= 440 V","Mechanical durability":"4 Mcycles","Mechanical robustness":"Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (8 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","Associated fuse rating":"200 A gG at 160 A gG at <= 690 V coordination type 2 for power circuit","Maximum operating rate":"3600 cyc/h 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1...2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1...4 mm² - cable stiffness: solid Control circuit: screw clamp terminals 2 1...4 mm² - cable stiffness: solid Power circuit: connector 1 4...50 mm² - cable stiffness: flexible without cable end Power circuit: connector 2 4...25 mm² - cable stiffness: flexible without cable end Power circuit: connector 1 4...50 mm² - cable stiffness: flexible with cable end Power circuit: connector 2 4...16 mm² - cable stiffness: flexible with cable end Power circuit: connector 1 4...50 mm² - cable stiffness: solid Power circuit: connector 2 4...25 mm² - cable stiffness: solid Control circuit: screw clamp terminals 1 1...2.5 mm² - cable stiffness: flexible with cable end","IP degree of protection":"IP20 front face conforming to IEC 60529","Rated breaking capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"4 NO","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Power dissipation per pole":"12.5 W AC-1","[Uc] control circuit voltage":"96 V DC","[Ui] rated insulation voltage":"Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.1...0.3 Uc (-40...70 °C):drop-out DC 0.75...1.2 Uc (-40...55 °C):operational DC 1...1.2 Uc (55...70 °C):operational DC","Hold-in power consumption in W":"22 W at 20 °C","[Ie] rated operational current":"125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: Power circuit: <= 300 V DC","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"135 A 40 °C - 10 min for power circuit 320 A 40 °C - 1 min for power circuit 640 A 40 °C - 10 s for power circuit 990 A 40 °C - 1 s for power circuit","[Ith] conventional free air thermal current":"125 A (at 60 °C) for power circuit","Permissible ambient air temperature around the device":"-60...80 °C storage -40...60 °C operation 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/0ff1e9aedb20e17f34824e5a493c06c3.pdf","sourceUrl":"https://www.se.com/sg/en/product/LP1D80004DW/contactor-tesys-deca4p4-no-ac1-440-v-125-a-96-v-dc-coil/"},"ai":{"faq":[{"question":"What compliance documentation does this brand provide?","answer":"The contactor is certified to CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, and UL 508. The front face is IP20 rated per IEC 60529."},{"question":"What are the key ratings of LP1D80004DW?","answer":"It is a 4-pole contactor with a 96 V DC coil, rated 125 A AC-1 (Ith), with breaking/making capacity of 1100 A at 440 V. Utilisation categories include AC-1, AC-3, AC-3e, and AC-4."},{"question":"What is the depth of LP1D80004DW?","answer":"The depth is 181 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D80004DW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D80004DW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}