{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D80004EW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D80004EW","canonicalUrl":"https://aoctrl.com/schneider/LP1D80004EW","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D80004EW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca contactor, 4-pole 4 NO, 80-150 A AC-1, DC wide-range coil, screw-clamp terminals, UL/CSA/IEC certified.","salesMarkdown":"The Schneider LP1D80004EW is a 4-pole, 4 NO contactor from the TeSys Deca range, rated for resistive loads in AC-1 utilisation category. It handles 80-150 A continuous current and is built for panel-mount applications where you need to switch heater banks, lighting, or other non-inductive loads. The DC wide-range coil (no built-in suppressor) means you supply your own flyback diode or RC snubber — plan for that on the control wiring. AC-1 rating is the key: this contactor is not rated for motor starting (AC-3) or inductive loads. The 80-150 A range covers resistive circuits like electric heat, lighting contactor banks, or power-factor correction capacitor switching. The 4-pole 4 NO configuration gives you four normally-open power poles — no auxiliary contacts built in, so you'll add a side-mount block if you need feedback to a PLC. Mechanical durability is 4 million cycles; electrical durability is 0.8 million cycles at 125 A AC-1 under 440 V. That's a solid lifespan for a heater-bank contactor that cycles maybe a few times per day. The rated breaking and making capacity is 1100 A at 440 V — enough to handle inrush from cold resistive loads without welding the contacts. Mounting is on a rail or plate (not DIN-rail snap-on — this is a bolt-down Deca frame). Depth is 7.1 in (181 mm), so allow that clearance behind the panel door. Power terminals accept up to 50 mm² cable; torque to 12 N·m. Control circuit terminals are screw clamp, 1-4 mm², torque 1.2 N·m. Certified to UL 508, CSA C22.2 No 14, IEC 60947-4-1, IEC 60947-5-1, and EN 60947-4-1/5-1. Flame retardance V1 per UL 94. Fire resistance to 1562 °F (850 °C) per IEC 60695-2-1.","metaTitle":"Schneider LP1D80004EW TeSys Deca Contactor, 4-Pole, 80-150 A","metaDescription":"Schneider LP1D80004EW TeSys Deca contactor, 4-pole 4 NO, rated 80-150 A AC-1 for resistive loads. UL/CSA/IEC certified, current production. Depth 181 mm.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"7.1 in (181 mm)","Range":"TeSys","Width":"3.8 in (96 mm)","Height":"5 in (127 mm)","Category":"22359-CTR,TESYS D,OPEN,80-150A AC&DC","Standards":"CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508","Time constant":"75 ms","Operating time":"6...20 ms opening 20...35 ms closing","Coil technology":"Without built-in suppressor module","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting Support":"Rail Plate","Pollution degree":"3","Protective cover":"Without","Range of Product":"TeSys Deca","Average impedance":"0.8 mOhm - Ith 125 A 50 Hz for power circuit","Device short name":"LP1D","Inrush power in W":"22 W 68 °F (20 °C))","Poles description":"4P","Tightening torque":"Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 Power circuit 106.2 lbf.in (12 N.m) connector flat Ø 6 to Ø 8 mm Power circuit 106.2 lbf.in (12 N.m) connector hexagonal 0.2 in (4 mm)","Compatibility code":"LP1D","Operating altitude":"0...9842.52 ft (0...3000 m)","Control circuit type":"DC wide range","Overvoltage category":"III","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"0.8 Mcycles 125 A AC-1 <= 440 V","Mechanical durability":"4 Mcycles","Mechanical robustness":"Vibrations contactor open 2 Gn, 5...300 Hz) Vibrations contactor closed 3 Gn, 5...300 Hz) Shocks contactor open 8 Gn for 11 ms) Shocks contactor closed 10 Gn for 11 ms)","Nbr. of units in pkg.":"1","Associated fuse rating":"200 A gG at 160 A gG at <= 690 V coordination type 2 for power circuit","Maximum operating rate":"3600 cyc/h at 60 °C","Connections - terminals":"Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 2 0.002...0.006 in² (1...4 mm²) - cable stiffness: solid Power circuit: connector 1 0.006...0.08 in² (4...50 mm²) - cable stiffness: flexible without cable end Power circuit: connector 2 0.006...0.04 in² (4...25 mm²) - cable stiffness: flexible without cable end Power circuit: connector 1 0.006...0.08 in² (4...50 mm²) - cable stiffness: flexible with cable end Power circuit: connector 2 0.006...0.02 in² (4...16 mm²) - cable stiffness: flexible with cable end Power circuit: connector 1 0.006...0.08 in² (4...50 mm²) - cable stiffness: solid Power circuit: connector 2 0.006...0.04 in² (4...25 mm²) - cable stiffness: solid Control circuit: screw clamp terminals 1 0.002...0.004 in² (1...2.5 mm²) - cable stiffness: flexible with cable end","IP degree of protection":"IP20 front face IEC 60529","Rated breaking capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"4 NO","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Contactor","Irms rated making capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Power dissipation per pole":"12.5 W AC-1","[Uc] control circuit voltage":"48 V DC","[Ui] rated insulation voltage":"Power circuit 600 V CSA Power circuit 600 V UL Power circuit 1000 V IEC 60947-4-1","Control circuit voltage limits":"0.1...0.3 Uc (-40...158 °F (-40...70 °C)):drop-out DC 0.75...1.2 Uc (-40...131 °F (-40...55 °C)):operational DC 1...1.2 Uc (131...158 °F (55...70 °C)):operational DC","Hold-in power consumption in W":"22 W 68 °F (20 °C)","[Ie] rated operational current":"125 A (at 80 A (at 80 A (at 55 A (at <140 °F (60 °C)) at <= 400 V AC AC-4 for power circuit","[Ue] rated operational voltage":"Power circuit Power circuit <= 300 V DC","[Uimp] rated impulse withstand voltage":"8 kV IEC 60947","[Icw] rated short-time withstand current":"135 A 104 °F (40 °C) - 10 min for power circuit 320 A 104 °F (40 °C) - 1 min for power circuit 640 A 104 °F (40 °C) - 10 s for power circuit 990 A 104 °F (40 °C) - 1 s for power circuit","[Ith] conventional free air thermal current":"125 A (at 140 °F (60 °C)) for power circuit","Permissible ambient air temperature around the device":"-40...140 °F (-40...60 °C) 140...158 °F (60...70 °C) with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8211decf955be8482b62ad00c04cbaf7.pdf","sourceUrl":"https://www.se.com/vn/en/product/LP1D80004EW/contactor-tesys-deca4p4-no-ac1-440-v-125-a-48-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1D80004EW/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative in the TeSys family?","answer":"The LP1D80004EW is the 4-pole Deca-frame contactor for resistive loads. If you need a smaller footprint for the same current range, the standard TeSys D series (e.g., LC1D80 through LC1D150) offers 3-pole AC-3 rated contactors, but those are a different frame and coil system — not a direct pin-compatible swap. The Deca frame is physically larger and built for higher continuous current."},{"question":"What compliance documentation does Schneider provide for this part?","answer":"The LP1D80004EW carries UL 508, CSA C22.2 No 14, IEC 60947-4-1, IEC 60947-5-1, and EN 60947-4-1/5-1 certifications. Flame retardance is V1 per UL 94. Standard RoHS/REACH declarations are available from Schneider's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D80004EW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D80004EW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}