{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1D800086SW","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1D800086SW","canonicalUrl":"https://aoctrl.com/schneider/LP1D800086SW","factsUrl":"https://aoctrl.com/api/mcp/products/LP1D800086SW","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys Deca LP1D800086SW, 4-pole contactor, 72 VDC coil, AC-1 utilisation category for resistive loads.","salesMarkdown":"The LP1D800086SW is a TeSys Deca 4-pole contactor from Schneider Electric, built for switching resistive loads under the AC-1 utilisation category. Its 72 VDC wide-range coil pulls in cleanly without a built-in suppressor module, so if your control voltage is a straight 72 VDC bus, this lands without extra parts. Rated for 125 A in AC-1 duty, it handles resistive heating banks, lighting stages, or transformer primary switching where the inrush stays moderate. The 4-pole arrangement gives you 2 NO + 2 NC main contacts, which is useful for splitting load phases or using one pole as a pre-charge path. It carries UL 60947-4-1, CSA C22.2 No 14, and IEC 60947-4-1 certifications, so it's accepted across North American and IEC panels without a second thought. Mounts on plate or DIN rail — 96 mm wide, 127 mm tall, 196 mm deep. That depth is the main dimension to check if you're shoehorning this into a shallow enclosure; it's a full 196 mm from the mounting surface to the back of the lug terminals. The power circuit lugs accept ring terminals up to 17 mm outer diameter or busbars up to 3 x 16 mm. No protective cover included — if your site spec calls for a shrouded terminal area, you'll add one separately.","metaTitle":"Schneider TeSys Deca LP1D800086SW Contactor, 72 VDC, 4P","metaDescription":"Schneider Electric TeSys Deca LP1D800086SW contactor. 4-pole, 72 VDC coil, AC-1 rated for resistive loads. UL/CSA/IEC certified. Current production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"196 mm","Range":"TeSys","Width":"96 mm","title":"LP1D800086SW","Height":"127 mm","Standards":"CSA C22.2 No 14 EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 60947-4-1","description":"Contactor, TeSys Deca, 4P(2NO+2NC), AC-1, <=440V, 125A, 72V DC wide range coil, ring-lug terminals","Time constant":"75 ms","Operating time":"6...20 ms opening 20...35 ms closing","Coil technology":"Without built-in suppressor module","Fire resistance":"850 °C conforming to IEC 60695-2-1","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting support":"Plate Rail","Pollution degree":"3","Protective cover":"Without","Range of product":"TeSys Deca","Average impedance":"0.8 mOhm - Ith 125 A 50 Hz for power circuit","Device short name":"LP1D","Inrush power in W":"22 W (at 20 °C)","Poles description":"4P","Tightening torque":"Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5 Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5 Power circuit: 12 N.m - on lugs-ring terminals hexagonal screw head 10 mm M6 Power circuit: 12 N.m - on lugs-ring terminals - with screwdriver flat Ø 8 mm M6 Power circuit: 12 N.m - on bars - with screwdriver flat Ø 8 mm M6 Power circuit: 12 N.m - on bars hexagonal screw head 10 mm M6 Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver pozidriv No 2 M3.5","Compatibility code":"LP1D","Operating altitude":"0...3000 m","Control circuit type":"DC wide range","Overvoltage category":"III","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"0.8 Mcycles 125 A AC-1 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Mechanical robustness":"Vibrations contactor open (2 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (8 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)","Associated fuse rating":"200 A gG at 160 A gG at <= 690 V coordination type 2 for power circuit","Maximum operating rate":"3600 cyc/h at 60 °C","Connections - terminals":"Control circuit: lugs-ring terminals - external diameter: 8 mm Power circuit: lugs-ring terminals - external diameter: 17 mm Power circuit: bars 1 - busbar cross section: 3 x 16 mm","IP degree of protection":"IP20 front face conforming to IEC 60529","Rated breaking capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"1100 A at 440 V for power circuit conforming to IEC 60947","Power dissipation per pole":"12.5 W AC-1","[Uc] control circuit voltage":"72 V DC","[Ui] rated insulation voltage":"Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1","Control circuit voltage limits":"0.1...0.3 Uc (-40...55 °C):drop-out DC 0.75...1.2 Uc (-40...55 °C):operational DC","Hold-in power consumption in W":"22 W at 20 °C","[Ie] rated operational current":"125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: <= 690 V AC 25...400 Hz","[Uimp] rated impulse withstand voltage":"8 kV conforming to IEC 60947","[Icw] rated short-time withstand current":"135 A 40 °C - 10 min for power circuit 320 A 40 °C - 1 min for power circuit 640 A 40 °C - 10 s for power circuit 990 A 40 °C - 1 s for power circuit","[Ith] conventional free air thermal current":"125 A (at 60 °C) for power circuit","Permissible ambient air temperature around the device":"-40...60 °C 60...70 °C with derating"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/79dd2a037b0872dc0c258dcfdee67fe4.pdf","sourceUrl":"https://www.se.com/ae/en/product/LP1D800086SW/contactor-tesys-deca-4p2no+2nc-ac1-440v-125a-72v-dc-wide-range-coil-ringlug-terminals/"},"ai":{"faq":[{"question":"What are its key ratings?","answer":"4-pole contactor, 72 VDC coil, AC-1 utilisation category for resistive loads. Rated breaking and making capacity is 1100 A at 440 V per IEC 60947. Electrical durability is 0.8 Mcycles at 125 A AC-1; mechanical durability is 10 Mcycles."},{"question":"What compliance documentation does Schneider provide for this part?","answer":"It carries UL 60947-4-1, CSA C22.2 No 14, IEC 60947-4-1, and EN 60947-4-1 certifications. Flame retardance is V1 per UL 94; fire resistance is 850 °C per IEC 60695-2-1."},{"question":"What is the closest alternative in the same family?","answer":"Within the TeSys Deca range, the closest sibling is a 4-pole contactor with the same AC-1 current rating but a different coil voltage. The deciding factor is your control bus — if it's not 72 VDC, you'd pick the variant that matches your DC supply. The mechanical footprint and terminal layout are identical across the LP1D family."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1D800086SW","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1D800086SW when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}