{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1K09004ZD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1K09004ZD","canonicalUrl":"https://aoctrl.com/schneider/LP1K09004ZD","factsUrl":"https://aoctrl.com/api/mcp/products/LP1K09004ZD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K LP1K09004ZD contactor, 4P (4 NO), AC-1 utilisation category, ≤440 V, 20 A, 20 V DC coil.","salesMarkdown":"The Schneider Electric LP1K09004ZD is a TeSys K contactor with 4 normally-open poles, rated for 20 A in AC-1 duty (resistive loads) at up to 690 V AC 50/60 Hz. The 20 V DC coil pulls in at 0.8 to 1.15 times nominal and drops out between 0.1 and 0.75 Uc below 50 °C. Coil hold-in power runs 3 W at 20 °C. The AC-1 rating means this contactor is sized for resistive loads — heaters, lighting banks, or transformer primaries — not for motor starting (which would need an AC-3 rating). The 4 NO pole arrangement gives four independent switching paths, all normally open; there are no NC auxiliary contacts built in. Rated breaking capacity hits 110 A at 415 V and 440 V, tapering to 70 A at 660–690 V. For safety-related circuits, the B10d value is 1,369,863 cycles under nominal load per EN/ISO 13849-1, or 20 million cycles with mechanical load only. Screw-clamp terminals accept a Philips No 2 or 6 mm flat screwdriver at 1.3 N·m torque. The power circuit impedance is 3 mΩ at 20 A, 50 Hz.","metaTitle":"Schneider LP1K09004ZD TeSys K Contactor, 4P 4NO, 20A AC-1, 2","metaDescription":"Schneider Electric TeSys K LP1K09004ZD contactor, 4P 4NO, 20A AC-1 rated operational current, 690V AC coil 20V DC. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","title":"LP1K09004ZD","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","description":"TeSys K contactor, 4P (4 NO),AC-1, <= 440V, 20A, 20V DC coil","Operating time":"30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Mounting support":"Rail Plate","Range of product":"TeSys K","Average impedance":"3 mOhm - Ith 20 A 50 Hz for power circuit","Device short name":"LP1K","Inrush power in W":"3 W (at 20 °C)","Poles description":"4P","Tightening torque":"1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm","Compatibility code":"LP1K","Operating altitude":"2000 m without derating","Overvoltage category":"III","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"25 A gG at 25 A aM for power circuit","Maximum operating rate":"3600 cyc/h","Rated breaking capacity":"110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947","Pole contact composition":"4 NO","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947","[Ui] rated insulation voltage":"Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA C22.2 No 14","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: 0.1...0.75 Uc (at <50 °C)","Hold-in power consumption in W":"3 W at 20 °C","[Ie] rated operational current":"20 A (at 16 A (at <70 °C) at 690 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Ith] conventional free air thermal current":"20 A (at 50 °C) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/bd531ef0755543934483e93397e6303c.pdf","sourceUrl":"https://www.se.com/mk/en/product/LP1K09004ZD/tesys-k-contactor-4p-4-no-ac1-440v-20a-20v-dc-coil/"},"ai":{"faq":[{"question":"What is the closest alternative within the TeSys K family?","answer":"Within the TeSys K family, the closest peer is another 4-pole contactor with the same coil voltage but a different current rating. The deciding factor is the 20 A AC-1 rating — if your load is lower, a 16 A variant may fit; if higher, step up to a 25 A version. Both share the same 45 mm width and mounting pattern."},{"question":"What compliance documentation is available for this part?","answer":"The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, GB/T 14048.4, and JIS C8201-4-1. Flame retardance is V1 per UL 94, and it also meets NF F 16-101 and NF F 16-102 for rail applications."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1K09004ZD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1K09004ZD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}