{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1K09008JD3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1K09008JD3","canonicalUrl":"https://aoctrl.com/schneider/LP1K09008JD3","factsUrl":"https://aoctrl.com/api/mcp/products/LP1K09008JD3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, 4P (2 NO + 2 NC), AC-1, ≤440 V, 20 A, 12 V DC coil.","salesMarkdown":"The LP1K09008JD3 is a TeSys K contactor from Schneider Electric, a 4-pole (2 NO + 2 NC) device rated for 20 A in AC-1 utilisation category at ≤ 440 V, with a 12 V DC coil. It is designed for switching resistive loads in control panels and industrial machinery. The 20 A conventional free-air thermal current (Ith) at 50 °C and the 20 A rated operational current (Ie) at 690 V AC in AC-1 duty mean this contactor handles resistive heating loads like heater banks or lighting circuits up to that current. The AC-1 rating is the key selection parameter — it governs the continuous current the contacts can carry without derating for inductive motor inrush. Mounts on a plate or DIN rail, with a 45 mm width, 58 mm height, and 57 mm depth — fits standard 45 mm modular enclosure spacing. Screw-clamp terminals accept a Philips No 2 or flat Ø 6 mm screwdriver, torqued to 1.3 N·m. The 12 V DC coil includes a built-in bidirectional peak limiting diode suppressor, so no external flyback diode is needed across the coil — saves a component and a wiring step. Coil energisation to NO closing takes 30…40 ms; de-energisation to NO opening takes 10 ms. The control circuit operates between 0.8 and 1.15 Uc and drops out between 0.1 and 0.75 Uc below 50 °C. Inrush power is 3 W at 20 °C; hold-in power consumption is also 3 W at 20 °C — the coil draws steady power once sealed, no spike after the initial pull-in. ## Breaking capacity and protection Rated breaking capacity reaches 110 A at 415 V and 440 V, 80 A at 500 V, and 70 A at 660…690 V, all conforming to IEC 60947. The rated making capacity is 110 A AC for the power circuit. For short-circuit protection, the associated fuse rating is 25 A gG or 25 A aM for the power circuit. Rated insulation voltage (Ui) is 690 V per IEC 60947-4-1, 600 V per UL 508 and CSA C22.2 No 14. Impulse withstand voltage (Uimp) is 8 kV, overvoltage category III — suitable for fixed-installation distribution panels where transient overvoltages from the mains are expected. Certified to EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Flame retardance meets V1 per UL 94 and Requirement 2 per NF F 16-101 and NF F 16-102. Safety reliability level: B10d = 1,369,863 cycles with nominal load and 20,000,000 cycles with mechanical load, per EN/ISO 13849-1. ## Environmental limits Operates at -25…50 °C ambient, stores at -50…80 °C. Maximum operating rate is 3600 cycles per hour. Mechanical durability is 10 million cycles.","metaTitle":"TeSys K LP1K09008JD3 Contactor, 4P 20A AC-1, 12V DC Coil","metaDescription":"Schneider TeSys K contactor LP1K09008JD3, 4P (2NO+2NC), 20A AC-1, 12V DC coil. Current production. UL/CSA/IEC/GB/JIS certified. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","title":"LP1K09008JD3","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","description":"TeSys K contactor, 4P (2 NO + 2 NC),AC-1, <= 440V, 20A, 12V DC coil","Operating time":"30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening 25...35 ms coil energisation and NC opening 15 ms coil de-energisation and NC closing","Coil technology":"Built-in bidirectional peak limiting diode suppressor","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Mounting support":"Plate Rail","Range of product":"TeSys K","Average impedance":"3 mOhm - Ith 20 A 50 Hz for power circuit","Device short name":"LP1K","Inrush power in W":"3 W (at 20 °C)","Poles description":"4P","Tightening torque":"1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm","Compatibility code":"LP1K","Operating altitude":"2000 m without derating","Overvoltage category":"III","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"25 A gG at 25 A aM for power circuit","Maximum operating rate":"3600 cyc/h","Rated breaking capacity":"110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947","[Ui] rated insulation voltage":"Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA C22.2 No 14","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: 0.1...0.75 Uc (at <50 °C)","Hold-in power consumption in W":"3 W at 20 °C","[Ie] rated operational current":"20 A (at 16 A (at <70 °C) at 690 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Ith] conventional free air thermal current":"20 A (at 50 °C) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8ade5127fcb68758ab6184ce186ca62c.pdf","sourceUrl":"https://www.se.com/be/en/product/LP1K09008JD3/tesys-k-contactor-4p-2-no-+-2-nc-ac1-440v-20a-12v-dc-coil/"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"The LP1K09008JD3 is a 4-pole (2 NO + 2 NC) contactor rated 20 A in AC-1 utilisation category at ≤ 440 V, with a 12 V DC coil. The conventional free-air thermal current (Ith) is 20 A at 50 °C. Breaking capacity reaches 110 A at 415/440 V."},{"question":"What compliance documentation does this part carry?","answer":"It is certified to EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Flame retardance is V1 per UL 94. Safety reliability is documented per EN/ISO 13849-1 with B10d values of 1,369,863 cycles (nominal load) and 20,000,000 cycles (mechanical load)."},{"question":"What are the physical dimensions of the LP1K09008JD3?","answer":"Width 45 mm, height 58 mm, depth 57 mm. It mounts on a plate or DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1K09008JD3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1K09008JD3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}