{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1K09008LD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1K09008LD","canonicalUrl":"https://aoctrl.com/schneider/LP1K09008LD","factsUrl":"https://aoctrl.com/api/mcp/products/LP1K09008LD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, 4P (2 NO + 2 NC), AC-1 ≤440V, 20A, 200V DC coil, LP1K09008LD.","salesMarkdown":"The Schneider Electric TeSys K LP1K09008LD is a 4-pole contactor with a 2 NO + 2 NC pole configuration, rated for 20 A in AC-1 utilisation category (resistive loads) at up to 690 V AC 50/60 Hz on the power circuit. The coil is 200 V DC. Rated breaking capacity reaches 110 A at 415 V, 440 V, 220…230 V, and 380…400 V per IEC 60947; 80 A at 500 V; and 70 A at 660…690 V. The conventional free-air thermal current (Ith) is 20 A at 50 °C for the power circuit. The 20 A AC-1 rating means this contactor is sized for resistive loads — heaters, lighting banks, or non-inductive circuits — not for motor starting. AC-1 is the least demanding switching duty; if your BOM calls for motor loads (AC-3), this part is underspecified. The 2 NO + 2 NC pole arrangement gives flexibility for interlocking or auxiliary switching within the same package. Rated insulation voltage (Ui) is 690 V per IEC 60947-4-1 and 600 V per UL 508 / CSA C22.2 No 14, with an impulse withstand voltage (Uimp) of 8 kV. Overvoltage category III means it's suitable for fixed-installation distribution panels, not for surge-prone outdoor feeders. Safety reliability data is published: B10d = 1,369,863 cycles for the contactor with nominal load per EN/ISO 13849-1, and B10d = 20,000,000 cycles with mechanical load only. This supports SIL/PL assessments for safety circuits using the NC mirror contacts. Mounts on rail or plate. Screw-clamp terminals accept a Philips No 2 or flat 6 mm screwdriver at 1.3 N·m torque. Maximum operating rate is 3600 cycles per hour.","metaTitle":"Schneider TeSys K LP1K09008LD Contactor, 4P 2NO+2NC, 20A AC-","metaDescription":"Active TeSys K contactor LP1K09008LD, 4-pole 2NO+2NC, 20A AC-1 at 690V, 200V DC coil. Rated breaking capacity 110A at 415V. UL/CSA/IEC certified. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","Operating time":"30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening 25...35 ms coil energisation and NC opening 15 ms coil de-energisation and NC closing","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Mounting support":"Rail Plate","Range of product":"TeSys K","Average impedance":"3 mOhm - Ith 20 A 50 Hz for power circuit","Device short name":"LP1K","Inrush power in W":"3 W (at 20 °C)","Poles description":"4P","Tightening torque":"1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm","Compatibility code":"LP1K","Operating altitude":"2000 m without derating","Overvoltage category":"III","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"25 A gG at 25 A aM for power circuit","Maximum operating rate":"3600 cyc/h","Rated breaking capacity":"110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947","Pole contact composition":"2 NO + 2 NC","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947","[Ui] rated insulation voltage":"Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA C22.2 No 14","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: 0.1...0.75 Uc (at <50 °C)","Hold-in power consumption in W":"3 W at 20 °C","[Ie] rated operational current":"20 A (at 16 A (at <70 °C) at 690 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Ith] conventional free air thermal current":"20 A (at 50 °C) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/in/en/product/LP1K09008LD/tesys-k-contactor-4p-2-no-+-2-nc-ac1-440v-20a-200v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1K09008LD/alternatives.json"},"ai":{"faq":[{"question":"What is the closest pin-compatible alternative in the TeSys family?","answer":"Within the TeSys K range, the LP1K series shares the same footprint and pole configuration. The key differentiator is the coil voltage — this unit uses a 200 V DC coil. A peer with a different coil voltage (e.g., 24 V DC or 230 V AC) would require a different order code but the same mechanical mounting and terminal layout."},{"question":"What is the depth of LP1K09008LD?","answer":"The depth is 57 mm."},{"question":"What is the product range for LP1K09008LD?","answer":"It belongs to the TeSys K range of contactors from Schneider Electric."},{"question":"What compliance documentation is available for LP1K09008LD?","answer":"The contactor is certified to EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Flame retardance is V1 per UL 94. Safety reliability data (B10d) per EN/ISO 13849-1 is published."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1K09008LD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1K09008LD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}