{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1K09106BD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1K09106BD","canonicalUrl":"https://aoctrl.com/schneider/LP1K09106BD","factsUrl":"https://aoctrl.com/api/mcp/products/LP1K09106BD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K, 3-pole contactor, AC-3/AC-3e 9A at 440V, 24V DC coil, 1NO auxiliary contact, IP2X.","salesMarkdown":"The LP1K09106BD is a TeSys K 3-pole contactor from Schneider Electric, rated for 9 A in AC-3 and AC-3e utilisation categories at 440 V, with a 24 V DC coil and one normally open auxiliary contact. The 3 NO power poles and 1 NO auxiliary contact give you the basic switching complement for a standalone motor starter or for integration into a larger control scheme. The 9 A AC-3 rating is the headline number that governs motor switching capacity — it is not a continuous thermal current but the rated operational current for making and breaking motor circuits. The contactor also carries AC-3e (enhanced) and AC-4 (inching/plugging) ratings, with electrical durability figures that drop sharply as duty gets harder: 1.3 million cycles at 9 A AC-3, 160,000 cycles at 20 A AC-1, and only 20,000 cycles at 54 A AC-4. ## Coil and control circuit details The control circuit voltage limits are 0.8 to 1.15 times the rated control voltage (Uc) for operation, and dropout occurs at or above 0.1 times Uc below 50 °C. There is no built-in suppressor module on the coil, so you will need to add a free-wheeling diode or RC snubber externally to protect the DC control circuit from inductive kickback. The coil energisation time is 30 to 40 ms for NO closing, and de-energisation (NO opening) takes 10 ms. ## Mounting, protection, and environment Operating temperature range is -25 to 50 °C, storage from -50 to 80 °C, and it can be used at altitudes up to 2000 m without derating. The terminals accept lugs or ring terminals with a 7 mm outer diameter. ## Standards and safety data The contactor complies with EN/IEC 60947-4-1 and -5-1, UL 60947-4-1 and -5-1, CSA C22.2 No 60947-4-1 and -5-1, and GB/T 14048.4. For functional safety applications, the B10d value is 1,369,863 cycles with nominal load and 20,000,000 cycles with mechanical load per EN/ISO 13849-1. The minimum switching current is 5 mA and minimum voltage 17 V for signalling circuits, which matters when the auxiliary contact drives a PLC input or a low-power relay. Flame retardance is V1 per UL 94 and meets NF F 16-101/102 requirements.","metaTitle":"TeSys K LP1K09106BD Contactor, 9A AC-3, 24V DC Coil","metaDescription":"Active TeSys K 3-pole contactor, 9A AC-3/AC-3e at 440V, 24V DC coil, 1NO aux. UL/CSA/IEC. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","title":"LP1K09106BD","Height":"58 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4","description":"Contactor, TeSys K, 3P, AC-3/AC-3e, 440V, 9A, 1NO aux, 24V DC coil","Operating time":"30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Mounting support":"Rail Plate","Device short name":"LP1K","Inrush power in W":"3 W (at 20 °C)","Poles description":"3P","Operating altitude":"2000 m without derating","Utilisation category":"AC-3 AC-3e AC-1 AC-4","Contactor application":"Resistive load Motor control","Electrical durability":"1.3 Mcycles 9 A AC-3 at Ue 1.3 Mcycles 9 A AC-3e at Ue 0.16 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 54 A AC-4 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NO","Connections - terminals":"Lugs-ring terminals (external diameter: 7 mm)","IP degree of protection":"IP2X","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: >= 0.10 Uc (at <50 °C)","Hold-in power consumption in W":"3 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1ec80a4480881c70ddd97c6839d5a804.pdf","sourceUrl":"https://www.se.com/sg/en/product/LP1K09106BD/contactor-tesys-k-3p-ac3-ac3e-440v-9a-1no-aux-24v-dc-coil/"},"ai":{"faq":[{"question":"What are the key ratings that decide fit for this contactor?","answer":"The headline rating is 9 A in AC-3/AC-3e utilisation category at 440 V, which governs its motor switching capacity. The coil is 24 V DC drawing 3 W hold-in power. The contactor has 3 NO power poles and 1 NO auxiliary contact. Dimensions are 45 mm wide, 58 mm high, 57 mm deep for DIN-rail mounting."},{"question":"What standards does this contactor comply with?","answer":"It complies with EN/IEC 60947-4-1 and 60947-5-1, UL 60947-4-1 and 60947-5-1, CSA C22.2 No 60947-4-1 and 60947-5-1, and GB/T 14048.4. It also carries B10d safety reliability data per EN/ISO 13849-1 and V1 flame retardance per UL 94."},{"question":"Does the coil have a built-in suppressor?","answer":"No, the coil technology is listed as 'without built-in suppressor module'. You will need to add an external free-wheeling diode or RC snubber across the coil to protect the DC control circuit from inductive voltage spikes during de-energisation."},{"question":"What is the minimum load the auxiliary contact can switch reliably?","answer":"The minimum switching current is 5 mA and minimum switching voltage is 17 V for the signalling circuit. Below these levels, the contact may not reliably wet the circuit, so avoid using it for dry-contact or very low-energy signals without verifying compatibility."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1K09106BD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1K09106BD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}