{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1K12004LD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1K12004LD","canonicalUrl":"https://aoctrl.com/schneider/LP1K12004LD","factsUrl":"https://aoctrl.com/api/mcp/products/LP1K12004LD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K LP1K12004LD, 4-pole (4 NO) contactor, AC-1 rated 20 A at ≤440 V, 200 V DC coil, obsolete.","salesMarkdown":"It carries a conventional free-air thermal current (Ith) of 20 A at 50 °C and a rated operational current (Ie) of 20 A at ≤440 V, 16 A at <70 °C, and 16 A at 690 V AC. The coil is 200 V DC, with an operational voltage range of 0.8 to 1.15 Uc and a drop-out range of 0.1 to 0.75 Uc below 50 °C. Rated breaking capacity reaches 110 A at 440 V, 80 A at 500 V, and 70 A at 660–690 V per IEC 60947. Rated making capacity is 144 A AC for the power circuit. The contactor is rated for impulse withstand voltage (Uimp) of 8 kV and insulation voltage (Ui) of 600 V per UL 508 / 690 V per IEC 60947-4-1. For safety-related applications, the B10d value is 1,369,863 cycles at nominal load and 20,000,000 cycles at mechanical load per EN/ISO 13849-1. Screw-clamp terminals accept a Philips No 2 or flat 6 mm screwdriver at 1.3 N·m torque. The 4-pole configuration with all NO contacts suits resistive load switching in control panels where galvanic isolation of multiple load circuits is needed.","metaTitle":"TeSys K LP1K12004LD Contactor, 4P 20A AC-1, Obsolete","metaDescription":"TeSys K LP1K12004LD contactor, 4P (4 NO), 20A AC-1 at 440V, 200V DC coil. Obsolete - sourced to order against RFQ. UL, CSA, IEC certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","Operating time":"30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Mounting support":"Rail Plate","Range of product":"TeSys K","Average impedance":"3 mOhm - Ith 20 A 50 Hz for power circuit","Device short name":"LP1K","Inrush power in W":"3 W (at 20 °C)","Poles description":"4P","Tightening torque":"1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm","Compatibility code":"LP1K","Operating altitude":"2000 m without derating","Overvoltage category":"III","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"25 A gG at 25 A aM for power circuit","Maximum operating rate":"3600 cyc/h","Rated breaking capacity":"110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947","Pole contact composition":"4 NO","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"144 A AC for power circuit conforming to NF C 63-110 144 A AC for power circuit conforming to IEC 60947","[Ui] rated insulation voltage":"Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA C22.2 No 14","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: 0.1...0.75 Uc (at <50 °C)","Hold-in power consumption in W":"3 W at 20 °C","[Ie] rated operational current":"20 A (at 16 A (at <70 °C) at 690 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Ith] conventional free air thermal current":"20 A (at 50 °C) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d9a0361c616d0f0401faf74d7c324d2a.pdf","sourceUrl":"https://www.se.com/mk/en/product/LP1K12004LD/tesys-k-contactor-4p-4-no-ac1-440v-20a-200v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1K12004LD/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to LP1K12004LD in the TeSys K family?","answer":"Schneider Electric does not publish a direct successor order code for this specific variant. A functionally similar TeSys K contactor with 4 NO poles and comparable AC-1 current rating may exist in the current LP1K product range, but pin compatibility and coil voltage must be verified against your application. Contact us with your requirements for a cross-reference search."},{"question":"What are the key ratings of LP1K12004LD?","answer":"4-pole (4 NO) contactor, AC-1 utilisation category, 20 A rated operational current at ≤440 V, 200 V DC coil. Breaking capacity 110 A at 440 V. Mechanical durability 10 million cycles."},{"question":"What compliance documentation does Schneider provide for LP1K12004LD?","answer":"The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Flame retardance is V1 per UL 94. It also meets NF F 16-101 and NF F 16-102 railway standards."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1K12004LD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1K12004LD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}