{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1K12004MD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1K12004MD","canonicalUrl":"https://aoctrl.com/schneider/LP1K12004MD","factsUrl":"https://aoctrl.com/api/mcp/products/LP1K12004MD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K contactor, LP1K12004MD, 4P (4 NO), AC-1 rated 20 A at 690 V, 220 V DC coil, obsolete.","salesMarkdown":"Its conventional free-air thermal current (Ith) is 20 A at 50 °C, and the rated operational current (Ie) is 20 A at 690 V AC, 50/60 Hz. The coil is 220 V DC. This contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1 — a fully documented compliance package for global panel builds. The AC-1 utilisation category rating of 20 A at 690 V means this contactor is designed for switching resistive loads — heaters, ovens, lighting banks — not motor starting. For motor duty (AC-3), a different TeSys K variant would be required. The 4 NO pole configuration gives four independent switching paths, all normally open. The mechanical durability of 10 million cycles and a maximum operating rate of 3600 cycles per hour suit it for high-duty-cycle resistive switching applications. The safety reliability level is documented with B10d values: 1,369,863 cycles at nominal load and 20,000,000 cycles at mechanical load, conforming to EN/ISO 13849-1. This makes the part traceable for functional-safety assessments in machine guarding circuits, provided the application matches the AC-1 load profile. Screw-clamp terminals accept a Philips No 2 or flat 6 mm screwdriver, torqued to 1.3 N·m.","metaTitle":"TeSys K LP1K12004MD Contactor 4P 20A 220VDC Coil, Obsolete","metaDescription":"TeSys K LP1K12004MD contactor, 4P (4 NO), AC-1 rated 20 A at 690 V, 220 V DC coil. Obsolete status — sourced to order against RFQ. Certified to EN/IEC 60947-4-1, UL 60947-4-1, CSA","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","Operating time":"30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Mounting support":"Plate Rail","Range of product":"TeSys K","Average impedance":"3 mOhm - Ith 20 A 50 Hz for power circuit","Device short name":"LP1K","Inrush power in W":"3 W (at 20 °C)","Poles description":"4P","Tightening torque":"1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm","Compatibility code":"LP1K","Operating altitude":"2000 m without derating","Overvoltage category":"III","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"25 A gG at 25 A aM for power circuit","Maximum operating rate":"3600 cyc/h","Rated breaking capacity":"110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947","Pole contact composition":"4 NO","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Contactor","Irms rated making capacity":"144 A AC for power circuit conforming to NF C 63-110 144 A AC for power circuit conforming to IEC 60947","[Ui] rated insulation voltage":"Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA C22.2 No 14","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: 0.1...0.75 Uc (at <50 °C)","Hold-in power consumption in W":"3 W at 20 °C","[Ie] rated operational current":"20 A (at 16 A (at <70 °C) at 690 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Ith] conventional free air thermal current":"20 A (at 50 °C) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1e947f7b443d111c86bdca52d0aaff81.pdf","sourceUrl":"https://www.se.com/ie/en/product/LP1K12004MD/tesys-k-contactor-4p-4-no-ac1-440v-20a-220v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1K12004MD/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a 4-pole (4 NO) contactor rated for AC-1 resistive loads at 20 A (Ie) at 690 V AC, with a conventional free-air thermal current (Ith) of 20 A at 50 °C. The coil is 220 V DC. It is certified to EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2."},{"question":"What compliance documentation is available for this part?","answer":"The part is certified to EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. The safety reliability is documented per EN/ISO 13849-1 with B10d values. Flame retardance is V1 per UL 94."},{"question":"What is the physical size of this contactor?","answer":"It measures 45 mm wide, 58 mm high, and 57 mm deep. It mounts on a plate or DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1K12004MD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1K12004MD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}