{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1K1210ED","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1K1210ED","canonicalUrl":"https://aoctrl.com/schneider/LP1K1210ED","factsUrl":"https://aoctrl.com/api/mcp/products/LP1K1210ED","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K LP1K1210ED, 3-pole contactor, 12 A at 440 V AC-3/AC-3e, 48 V DC coil, 1 NO auxiliary contact, screw clamp terminals.","salesMarkdown":"The Schneider Electric LP1K1210ED is a 3-pole contactor from the TeSys K series, rated 12 A in AC-3/AC-3e duty at 440 V, with a 48 V DC coil and one normally open auxiliary contact. The AC-3e rating (12 A) extends this to energy-efficient motors with higher inrush. For resistive loads (AC-1), the contactor handles 20 A. The mechanical durability of 10 Mcycles and electrical durability of 1.3 Mcycles at AC-3 mean this contactor is built for moderate-cycle applications like conveyors or pumps, not high-speed indexing. The 48 V DC coil draws 3 W inrush and hold-in power at 20 °C, with an operating range of 0.8 to 1.15 times the control voltage (Uc). Drop-out occurs at ≥ 0.10 Uc below 50 °C — important for control circuit design where undervoltage release is needed. The coil has no built-in suppressor module, so an external flyback diode or RC snubber should be added to protect the DC control circuit. The contactor carries a B10d of 1,369,863 cycles at nominal load per EN/ISO 13849-1, making it suitable for safety-related circuits where the contactor is part of a monitored safety function. The minimum switching capability of 5 mA at 17 V ensures reliable signalling even with low-energy control signals. ## Sourcing Reality: Obsolete Part This part is classified as obsolete by the manufacturer. For a BOM line or installed base that requires this exact code, sourcing is through surplus or broker channels. ## Integration Notes Tightening torque is 0.8 to 1.3 N·m. IP2X protection means it is not suitable for washdown or outdoor use without an enclosure.","metaTitle":"TeSys K LP1K1210ED Contactor, 12A, 48V DC Coil, Obsolete","metaDescription":"Obsolete TeSys K LP1K1210ED contactor, 3P, 12A AC-3, 48V DC coil, 1NO aux. Sourced to order against RFQ. Standards: EN/IEC 60947-4-1, UL 60947-4-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"45 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4","Operating time":"30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening","Coil technology":"Without built-in suppressor module","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.3 W","Mounting support":"Rail Plate","Device short name":"LP1K","Inrush power in W":"3 W (at 20 °C)","Poles description":"3P","Tightening torque":"0.8...1.3 N.m - on screw clamp terminals Philips No 2 0.8...1.3 N.m - on screw clamp terminals flat Ø 6 mm 0.8...1.3 N.m - on screw clamp terminals pozidriv No 2","Operating altitude":"2000 m without derating","Utilisation category":"AC-3 AC-3e AC-1 AC-4","Contactor application":"Motor control Resistive load","Electrical durability":"1.3 Mcycles 12 A AC-3 at Ue 1.3 Mcycles 12 A AC-3e at Ue 0.3 Mcycles 20 A AC-1 at Ue 0.02 Mcycles 72 A AC-4 at Ue <= 440 V","Mechanical durability":"10 Mcycles","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"type instantaneous 1 NO","Connections - terminals":"Screw clamp terminals 1 cable(s) 1.5...4 mm²solid Screw clamp terminals 1 cable(s) 0.75...4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34...2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5...4 mm²solid Screw clamp terminals 2 cable(s) 0.75...4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34...1.5 mm²flexible with cable end Power circuit: screw clamp terminals 2 cable(s) 1.5 mm²flexible with cable end","IP degree of protection":"IP2X","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or component type":"Contactor","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: >= 0.10 Uc (at <50 °C)","Hold-in power consumption in W":"3 W at 20 °C","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c7b571d8dce284e964bb26fa4fff0f18.pdf","sourceUrl":"https://www.se.com/ae/en/product/LP1K1210ED/contactor-tesys-k-3p-ac3-ac3e-440v-12a-1no-aux-48v-dc-coil-screw-clamp-terminals/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1K1210ED/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation is available for LP1K1210ED?","answer":"The contactor complies with EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, and GB/T 14048.4. It also meets flame retardance V1 per UL 94 and NF F 16-101/102."},{"question":"What are the key ratings of LP1K1210ED?","answer":"It is a 3-pole contactor rated 12 A at 440 V in AC-3/AC-3e duty, with a 48 V DC coil and 1 NO auxiliary contact. Mechanical durability is 10 Mcycles; electrical durability is 1.3 Mcycles at AC-3."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1K1210ED","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1K1210ED when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}