{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP1SK0600SD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP1SK0600SD","canonicalUrl":"https://aoctrl.com/schneider/LP1SK0600SD","factsUrl":"https://aoctrl.com/api/mcp/products/LP1SK0600SD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys SK series, LP1SK0600SD mini contactor, 2P (2 NO), AC-1 rated 12 A at 690 V, 72 V DC coil, DIN-rail mount.","salesMarkdown":"The LP1SK0600SD is a TeSys SK mini contactor from Schneider Electric, built as a 2-pole normally-open (2 NO) device. It's rated for resistive loads in AC-1 utilisation category, carrying 12 A continuously at up to 690 V AC. The coil is 72 V DC, so it fits control circuits that run on a DC bus — common in panel designs where you want to avoid AC hum and keep the coil suppression simple. The 12 A AC-1 rating is the continuous resistive current it can switch — think heaters, ovens, or lamp banks. That's not a motor rating; AC-3 (motor) current would be lower, so if you're switching an induction motor, this isn't the contactor for that job. Coil pickup is 8...12 ms, dropout is 4...6 ms — fast enough for most sequencing but not a high-speed application. The control voltage limits are 0.85...1.1 Uc for operation and 0.1...0.75 Uc for dropout at <50 °C, so the 72 V coil holds in down to about 61 V and drops out below about 54 V. That's a standard DC margin; just ensure your supply stays above 61 V under load. That's fine for on/off control of a resistive load in a process line, but not for PWM or fast cycling like a welding gun. It snaps onto a DIN rail (35 mm), and the footprint is 27 mm wide by 56 mm tall by 55.5 mm deep — a compact 2-pole block that fits in a crowded enclosure. The IP2X protection (finger-safe) means it's fine inside a panel but not for exposed mounting. Wire termination is via screw connectors: accepts 0.35...6 mm² solid or flexible (with/without ferrule), and up to two conductors per terminal for daisy-chaining. Tightening torque is 0.8 N.m with a Pozidriv No 1 bit. Heat dissipation is 2.2 W at 20 °C — negligible in a ventilated panel, but worth noting if you're packing dozens of these in a sealed enclosure. The operating temperature range is -20...50 °C, storage is -50...70 °C, and it's rated for 2000 m altitude without derating.","metaTitle":"TeSys SK LP1SK0600SD Mini Contactor, 12 A AC-1, 72 VDC Coil","metaDescription":"Schneider TeSys SK LP1SK0600SD mini contactor, 2P (2 NO), 12 A AC-1 at 690 V, 72 V DC coil. Current production. Complies with EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2. DIN-rail mo","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"55.5 mm","Range":"TeSys","Width":"27 mm","Height":"56 mm","Standards":"EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1","Operating time":"4...6 ms coil de-energisation and NO opening 8...12 ms coil energisation and NO closing","lifecycle_stage":"current","Heat dissipation":"2.2 W","Mounting support":"Rail","Average impedance":"4 mOhm - Ith 12 A 50 Hz","Device short name":"LP1SK","Inrush power in W":"2.2 W (at 20 °C)","Tightening torque":"0.8 N.m - on connector - with screwdriver pozidriv No 1","Operating altitude":"2000 m without derating","Control circuit type":"DC standard","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50015","Utilisation category":"AC-1","Contactor application":"Resistive load","Mechanical durability":"10 Mcycles","Associated fuse rating":"16 A gI at <= 440 V for power circuit conforming to IEC 60947","Maximum operating rate":"1200 cyc/h","Connections - terminals":"Power circuit: connector 1 cable(s) 0.35...6 mm²flexible with cable end Power circuit: connector 1 cable(s) 0.5...6 mm²flexible without cable end Power circuit: connector 1 cable(s) 1.5...6 mm²solid Power circuit: connector 2 cable(s) 0.35...1.5 mm²flexible with cable end Power circuit: connector 2 cable(s) 0.35...2.5 mm²flexible without cable end Power circuit: connector 2 cable(s) 1.5...4 mm²solid","IP degree of protection":"IP2X conforming to VDE 0106","Rated breaking capacity":"52 A at 52 A at <= 400 V for power circuit conforming to IEC 60947","Pole contact composition":"2 NO","Product or component type":"Mini contactor","Irms rated making capacity":"66 A at 690 V AC conforming to IEC 60947 66 A at 690 V AC conforming to NF C 63-110","[Uc] control circuit voltage":"72 V DC","[Ui] rated insulation voltage":"690 V conforming to IEC 60947 690 V conforming to VDE 0110 group C 690 V conforming to BS 5424 690 V conforming to UL 508 690 V conforming to CSA C22.2 No 14","Control circuit voltage limits":"Operational: 0.85...1.1 Uc (at Drop-out: 0.1...0.75 Uc (at <50 °C)","Hold-in power consumption in W":"2.2 W at 20 °C","Power Pole Contact Composition":"2P","[Ie] rated operational current":"12 A (at <55 °C) AC AC-1","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz","Ambient air temperature for storage":"-50...70 °C","Ambient air temperature for operation":"-20...50 °C","[Icw] rated short-time withstand current":"50 A 55 °C for power circuit","[Ith] conventional free air thermal current":"12 A (at 55 °C) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/410009524bec15d1c98169ed78a5f088.pdf","sourceUrl":"https://www.se.com/be/en/product/LP1SK0600SD/tesys-sk-mini-contactor-2p-2-no-ac1-690-v-12-a-72-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP1SK0600SD/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to the LP1SK0600SD in the TeSys SK family?","answer":"Within the TeSys SK range, the closest alternative would be a different coil voltage variant (e.g., 24 V DC or 48 V DC) or a 1-pole version. The 2-pole 72 V DC coil configuration is specific to this order code; swapping coil voltage means selecting a different SK part number. No direct pin-compatible drop-in exists if the coil voltage must match."},{"question":"What compliance documentation does Schneider provide for the LP1SK0600SD?","answer":"The contactor is certified to EN/IEC 60947-4-1, UL 60947-4-1, and CSA C22.2 No 60947-4-1. The protective treatment conforms to IEC 60068 and DIN 50015. Schneider typically provides a Declaration of Conformity (CE/UKCA) and a UL/CSA file number with the shipment; request the specific document set with your RFQ."},{"question":"What are the key electrical ratings for the LP1SK0600SD?","answer":"Rated operational current (Ie) is 12 A in AC-1 at ≤55 °C. Rated operational voltage (Ue) is 690 V AC 50/60 Hz. Rated insulation voltage (Ui) is 690 V. Conventional free air thermal current (Ith) is 12 A at 55 °C. Rated short-time withstand current (Icw) is 50 A at 55 °C. Coil voltage (Uc) is 72 V DC."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP1SK0600SD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP1SK0600SD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}