{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K06013ED","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K06013ED","canonicalUrl":"https://aoctrl.com/schneider/LP2K06013ED","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K06013ED","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K06013ED, 3P, AC-3 <=440 V 6 A, 1 NC, 48 V DC coil, preassembled with reversing power busbar.","salesMarkdown":"It's a 3-pole (3P) contactor rated for AC-3 duty up to 6 A at 440 V, which means it's sized for reversing a small three-phase motor — think conveyor drives, pump direction changes, or actuator control in a panel. The coil is 48 V DC, so it pulls in cleanly on a 48 VDC control supply; hold-in power is low, but make sure your DC supply can deliver the inrush. The 690 V AC rated operational voltage on the power circuit gives headroom for 400/480 V line supplies. It's IP20 finger-safe per VDE 0106, so it's intended for installation inside an enclosure, not exposed to washdown. The preassembled reversing busbar saves panel wiring time and reduces the chance of a phase-to-phase short during commissioning. Mechanical robustness is rated for 15 Gn shock on the closed-contactor Z axis and 4 Gn vibration closed — solid for industrial cabinet use, not for direct machine mounting on a vibrating frame. ## What the approvals tell you Flame retardance is V1 per UL 94 and also meets NF F 16-101 and NF F 16-102 — relevant if this panel goes into rail or transit applications. Protective treatment conforms to IEC 60068 and DIN 50016 for environmental resistance.","metaTitle":"TeSys K LP2K06013ED reversing contactor, 3P, AC-3 6A, 48 VDC","metaDescription":"TeSys K LP2K06013ED reversing contactor, 3P, AC-3 <=440V 6A, 1 NC, 48 VDC coil. Active production. IP20, 690V AC rated. Preassembled with reversing busbar.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K06013ED","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 6 A, 1 NC, 48 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-3","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/39ee2e463271547cd5c09b469c4fc0b4.pdf","sourceUrl":"https://www.se.com/ie/en/product/LP2K06013ED/tesys-k-reversing-contactor-3p-ac3-440-v-6-a-1-nc-48-v-dc-coil/"},"ai":{"faq":[{"question":"What is the closest alternative to LP2K06013ED in the TeSys K family?","answer":"Within the TeSys K reversing contactor range, the key differentiator is the coil voltage. The LP2K06013ED uses a 48 V DC coil. If your control voltage is different, look for other LP2K variants with the same AC-3 6 A rating but a different coil code — the last two digits of the order code typically indicate coil voltage. There is no pin-compatible drop-in with a different coil; you select by coil voltage."},{"question":"What is the depth of LP2K06013ED?","answer":"The depth is 57 mm. Overall dimensions are 90 mm wide by 58 mm high by 57 mm deep."},{"question":"What compliance documentation is available for LP2K06013ED?","answer":"The contactor carries UL 94 V1 flame retardance rating and conforms to NF F 16-101 and NF F 16-102 for rail applications. Protective treatment meets IEC 60068 and DIN 50016. The IP20 rating is per VDE 0106. Standard Schneider Electric declarations for RoHS and REACH are available through their documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K06013ED","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K06013ED when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}