{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K06013FD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K06013FD","canonicalUrl":"https://aoctrl.com/schneider/LP2K06013FD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K06013FD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 6 A, 1 NC, 110 V DC coil, preassembled with reversing power busbar, IP20.","salesMarkdown":"The LP2K06013FD is a TeSys K reversing contactor from Schneider Electric, rated for 3-pole motor control in AC-3 duty up to 6 A at 440 V, with a 110 V DC coil and one NC auxiliary contact. It ships preassembled with the reversing power busbar — no separate wiring of the mechanical interlock or power crossover needed, which saves panel-build time on a reversing starter. The contactor also carries an AC-4 rating for plugging and inching duty, where the motor is reversed or stopped by counter-torque, which stresses the contacts harder. For a small reversing starter on a conveyor, pump, or fan, this part covers the common 3-phase motor range up to roughly 2.2 kW at 400 V. IP20 finger-safe terminals (per VDE 0106) mean it can sit in a standard enclosure without additional shrouding on the line side. The preassembled reversing busbar keeps the phase crossover internal, so the only field wiring is the incoming power, the motor leads, and the 110 V DC coil circuit. The 110 V DC coil draws a holding current that depends on the specific coil power — verify the coil inrush and seal VA against your DC supply rating. The single NC auxiliary contact (1 NC) is typically wired into the opposite contactor's coil circuit as an electrical interlock, supplementing the mechanical interlock built into the reversing busbar assembly.","metaTitle":"Schneider Electric LP2K06013FD TeSys K reversing contactor,","metaDescription":"TeSys K reversing contactor LP2K06013FD, 3P, AC-3 <=440 V 6 A, 1 NC, 110 V DC coil. Active production. IP20. Preassembled reversing busbar. RFQ for quantity.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K06013FD","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 6 A, 1 NC, 110 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/359dbdbdcee6d67318f16ab6dc2065be.pdf","sourceUrl":"https://www.se.com/in/en/product/LP2K06013FD/tesys-k-reversing-contactor-3p-ac3-440-v-6-a-1-nc-110-v-dc-coil/"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"3-pole, AC-3 motor-switching duty at 6 A up to 440 V, also rated AC-4 for plugging and inching. Coil is 110 V DC. One NC auxiliary contact. Preassembled with reversing power busbar. IP20 finger-safe terminals."},{"question":"What is the physical size of the LP2K06013FD?","answer":"90 mm wide, 58 mm high, 57 mm deep. Mounts on 35 mm DIN rail."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries V1 flame retardance per UL 94, IP20 per VDE 0106, and protective treatment per IEC 60068 and DIN 50016. It also meets NF F 16-101 and NF F 16-102 for rail fire-smoke-toxicity. Standard Schneider documentation (datasheet, CE declaration, UL file) is available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K06013FD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K06013FD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}