{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K0601ED3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K0601ED3","canonicalUrl":"https://aoctrl.com/schneider/LP2K0601ED3","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K0601ED3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K0601ED3, 3P, AC-3 <= 440 V 6 A, 1 NC auxiliary, 48 V DC coil, preassembled with reversing power busbar.","salesMarkdown":"## What this reversing contactor is and why it matters The LP2K0601ED3: It is preassembled with a reversing power busbar, so the mechanical interlock and bus work are already in place for a motor reversing pair. At 6 A AC-3, it handles a 2.2 kW (3 HP) motor at 400 V three-phase. ## Lifecycle status and sourcing reality This part is marked obsolete by the manufacturer. Availability runs through independent surplus and broker channels. Quantities are lot-specific and confirmed at RFQ — no stock-holding claim is made here. The genuine part is sourced per the BOM line; same part, different passport. The contactor measures 2.2 in (57 mm) deep, 3.5 in (90 mm) wide, and 2.3 in (58 mm) high. The IP20 finger-safe enclosure (VDE 0106) means it can be mounted in a control cabinet without additional shrouding on the front face, though the power terminals remain touch-safe only to the IP20 standard. Flame retardance is V1 per UL 94, with additional compliance to NF F 16-101 and NF F 16-102 — relevant for rolling-stock or rail-adjacent installations where fire-smoke-toxicity requirements apply. Operating altitude is 2000 m without derating; above that, the dielectric strength and thermal dissipation must be recalculated per IEC 60947-1.","metaTitle":"Schneider LP2K0601ED3 TeSys K Reversing Contactor, 6A AC-3","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 6A at 440V, 48V DC coil, 1 NC. Sourced to order against RFQ via independent distribution. LP2K0601ED3 supplier.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"2.2 in (57 mm)","Range":"TeSys","Width":"3.5 in (90 mm)","Height":"2.3 in (58 mm)","Category":"22322-CTR,K-LINE,DC,OPEN,REV","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device Application":"Control","Operating altitude":"6561.68 ft (2000 m) without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC IEC 60068 TC DIN 50016","Utilisation category":"AC-3 AC-4","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 Shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","IP degree of protection":"IP20 VDE 0106","Product or Component Type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit 690 V AC 50/60 Hz Signalling circuit 10 MOhm for signalling circuit","Ambient Air Temperature for Storage":"-58...176 °F (-50...80 °C)","Ambient Air Temperature for Operation":"-13...122 °F (-25...50 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$38.05","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://www.se.com/ie/en/product/LP2K0601ED3/tesys-k-reversing-contactor-3p-ac3-440-v-6-a-1-nc-48-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K0601ED3/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for the LP2K0601ED3?","answer":"The utilisation category covers both AC-3 and AC-4 duty. The coil is 48 V DC, so confirm your control voltage matches — this is not a 24 V or 110 V unit."},{"question":"What compliance documentation does the LP2K0601ED3 carry?","answer":"The contactor is rated IP20 per VDE 0106 and carries UL 94 V1 flame retardance, with additional compliance to NF F 16-101 and NF F 16-102 for rail applications. The protective treatment follows IEC 60068 and DIN 50016."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K0601ED3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K0601ED3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}