{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K0601JD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K0601JD","canonicalUrl":"https://aoctrl.com/schneider/LP2K0601JD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K0601JD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K0601JD, 3P, AC-3 ≤440V 6A, 1 NC, 12VDC coil, preassembled with reversing power busbar.","salesMarkdown":"The 12 VDC coil keeps control-circuit wiring low-voltage, which simplifies panel layout when the PLC or relay outputs are DC-powered. Dimensions are 2.2 in (57 mm) deep, 3.5 in (90 mm) wide, and 2.3 in (58 mm) tall — a compact footprint that fits standard DIN-rail or panel-mount layouts without crowding adjacent devices. IP20 finger-safe protection (VDE 0106) means it is suited for enclosed control panels where operators may reach inside; no special shrouding is needed for basic touch protection. Rated for operation from -13 to 122 °F (-25 to 50 °C) and storage from -58 to 176 °F (-50 to 80 °C), it covers most industrial environments without derating, including unheated warehouses. Flame retardance meets UL 94 V1 and NF F 16-101/102, so it passes the material-level fire-safety checks often required in rail and building-services panels. ## Electrical and application notes Rated operational voltage on the power circuit is 690 V AC 50/60 Hz, but the AC-3 motor-switching rating is specified at ≤440 V — the higher 690 V figure applies to AC-1 resistive or low-inrush loads, not motor starting. The contactor carries AC-4 (inching/plugging) and AC-3e (enhanced motor) utilisation categories alongside AC-3, so it is rated for the higher electrical wear of frequent reversals or jogging duty. Mechanical robustness is specified to 15 Gn shock on the Z axis when closed and 4 Gn vibration (5–300 Hz) — enough for most industrial machinery but worth checking if the panel is mounted on a high-vibration press or mobile equipment. Operating altitude is 2000 m without derating; above that, dielectric withstand and thermal dissipation both decrease, so factor in if the installation is at high elevation.","metaTitle":"LP2K0601JD TeSys K Reversing Contactor, 6A AC-3, 12VDC Coil","metaDescription":"Active TeSys K reversing contactor, 3P, AC-3 ≤440V 6A, 1 NC, 12VDC coil. Preassembled with reversing power busbar. IP20. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"2.2 in (57 mm)","Range":"TeSys","Width":"3.5 in (90 mm)","title":"LP2K0601JD","Height":"2.3 in (58 mm)","Category":"22322-CTR,K-LINE,DC,OPEN,REV","description":"Reversing contactor, TeSys K, 3P, AC-3, lt or eq to 440V 6A, 1 NC, 12VDC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device Application":"Control","Operating altitude":"6561.68 ft (2000 m) without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC IEC 60068 TC DIN 50016","Utilisation category":"AC-3 AC-4 AC-3e","Contactor application":"Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 Shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","IP degree of protection":"IP20 VDE 0106","Product or Component Type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit 690 V AC 50/60 Hz Signalling circuit 10 MOhm for signalling circuit","Ambient Air Temperature for Storage":"-58...176 °F (-50...80 °C)","Ambient Air Temperature for Operation":"-13...122 °F (-25...50 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d3a0f961a2164063a18f15ee23be3cfb.pdf","sourceUrl":"https://www.se.com/us/en/product/LP2K0601JD/reversing-contactor-tesys-k-3p-ac3-lt-or-eq-to-440v-6a-1-nc-12vdc-coil/"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"AC-3 motor-switching rating is 6 A at ≤440 V with a 12 VDC coil. It has 3 NO power poles and 1 NC auxiliary contact, preassembled with a reversing power busbar."},{"question":"What is the physical size of the LP2K0601JD?","answer":"Depth is 2.2 in (57 mm), width is 3.5 in (90 mm), and height is 2.3 in (58 mm)."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries UL 94 V1 flame retardance and meets NF F 16-101/102 for rail applications. IP20 protection is per VDE 0106. Standard Schneider Electric declarations (RoHS, REACH, CE) apply to the TeSys K series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K0601JD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K0601JD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}