{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K09004FD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K09004FD","canonicalUrl":"https://aoctrl.com/schneider/LP2K09004FD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K09004FD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K LP2K09004FD, changeover contactor, 4 poles, 110 V DC control, AC-1 utilisation category, preassembled with reversing power busbar.","salesMarkdown":"Rated in utilisation category AC-1, it is designed for resistive loads — think heater banks, lighting, or transformer primary switching — where the current waveform stays near sinusoidal and contact erosion from inrush is minimal. The 110 V DC coil pulls 3 W at 20 °C to hold in, with an operating range of 0.8 to 1.15 Uc and a drop-out band of 0.1 to 0.75 Uc below 50 °C, so it stays picked through brownout conditions but drops cleanly when the control signal is removed. Breaking capacity is listed per IEC 60947 across multiple voltage points: 110 A at 415 V and 440 V, 80 A at 500 V, 70 A at 660–690 V. Electrical durability is 0.18 Mcycles at 20 A, AC-1, up to 440 V. That is about 180,000 operations at rated resistive load — enough for a moderate-duty cycling application. Mechanical durability is 5 Mcycles, so the mechanism outlasts the electrical contacts by a wide margin; plan contact inspection around the electrical life figure. Safety reliability is quantified with a B10d of 1,369,863 cycles at nominal load and 20,000,000 cycles at mechanical load per EN/ISO 13849-1 — useful if this contactor sits in a safety-related control circuit where you need to calculate the probability of dangerous failure per channel. Mounts on a rail or plate — the DIN-rail clip is standard for panel integration, and the screw-clamp terminals accept 0.34 to 4 mm² flexible or solid wire, with a tightening torque of 0.8 to 1.3 N·m using a No. 2 Phillips or 6 mm flat blade. No special minimums or custom-manufacturing lead times apply.","metaTitle":"Schneider Electric LP2K09004FD TeSys K Changeover Contactor,","metaDescription":"Schneider Electric LP2K09004FD TeSys K changeover contactor, 4 poles, 110 VDC coil, AC-1 rated for resistive loads. Active production. UL/CSA/IEC certified. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","Product name":"TeSys K","Operating time":"30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"3 W","Mounting support":"Rail Plate","Average impedance":"3 mOhm - Ith 20 A 50 Hz for power circuit","Device short name":"LP2K","Inrush power in W":"3 W (at 20 °C)","Interlocking type":"Mechanical","Poles description":"4P","Tightening torque":"0.8...1.3 N.m - on screw clamp terminals Philips No 2 0.8...1.3 N.m - on screw clamp terminals flat Ø 6 mm","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Control circuit type":"DC standard","Overvoltage category":"III","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"0.18 Mcycles 20 A AC-1 at Ue <= 440 V","Mechanical durability":"5 Mcycles","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","Associated fuse rating":"25 A gG at 25 A aM for power circuit","Maximum operating rate":"3600 cyc/h","Connections - terminals":"Screw clamp terminals 1 cable(s) 1.5...4 mm²solid Screw clamp terminals 1 cable(s) 0.75...4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34...2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5...4 mm²solid Screw clamp terminals 2 cable(s) 0.75...4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34...1.5 mm²flexible with cable end","IP degree of protection":"IP20 conforming to VDE 0106","Rated breaking capacity":"110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Changeover contactor","Irms rated making capacity":"110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947","[Uc] control circuit voltage":"110 V DC","[Ui] rated insulation voltage":"Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA C22.2 No 14","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: 0.1...0.75 Uc (at <50 °C)","Hold-in power consumption in W":"3 W at 20 °C","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"20 A (at 16 A (at <70 °C) at 690 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"90 A 50 °C - 1 s for power circuit 85 A 50 °C - 5 s for power circuit 80 A 50 °C - 10 s for power circuit 60 A 50 °C - 30 s for power circuit 45 A 50 °C - 1 min for power circuit 40 A 50 °C - 3 min for power circuit 20 A 50 °C - >= 15 min for power circuit","[Ith] conventional free air thermal current":"20 A (at 50 °C) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ba2944d6a2a274d3cb2a9f8c13346ec3.pdf","sourceUrl":"https://www.se.com/ie/en/product/LP2K09004FD/tesys-k-changeover-contactor-4p-ac1-440-v-20-a-110-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K09004FD/alternatives.json"},"ai":{"faq":[{"question":"What compliance documentation does Schneider provide for this contactor?","answer":"The LP2K09004FD carries certifications to EN/IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1, GB/T 14048.4, and JIS C8201-4-1. It also meets V1 flame retardance per UL 94 and railway fire-behaviour standards NF F 16-101 and NF F 16-102."},{"question":"What is the depth of the LP2K09004FD?","answer":"The LP2K09004FD has a depth of 57 mm, with a width of 90 mm and a height of 58 mm, fitting standard DIN-rail or plate-mount panel layouts."},{"question":"What is the closest alternative to the LP2K09004FD in the TeSys K family?","answer":"Within the TeSys K range, the closest peer is a standard 4-pole contactor without the preassembled reversing busbar. The LP2K09004FD is specifically a changeover contactor with the busbar included, so the alternative would require adding a separate reversing kit to a base contactor — not a direct pin-compatible drop-in."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K09004FD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K09004FD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}