{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K09015BDTQ","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K09015BDTQ","canonicalUrl":"https://aoctrl.com/schneider/LP2K09015BDTQ","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K09015BDTQ","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K09015BDTQ, 3-pole, AC-3/AC-3e, 9 A at 440 V, 24 V DC coil, mechanical interlock, active production.","salesMarkdown":"The LP2K09015BDTQ is a reversing contactor from the TeSys K series, built for motor control in applications where direction reversal is needed — conveyors, hoists, pumps, and similar three-phase loads. It's a 3-pole unit rated 9 A in AC-3 (motor switching) at 440 V, with a 24 V DC coil. The mechanical interlock between the two contactors inside the assembly prevents both from closing simultaneously, which is the standard way to avoid phase-to-phase shorts on a reversing starter. Coil suppression is built in — a bidirectional peak-limiting diode — so you don't need to add an external snubber across the coil. That saves a component and a wiring step on the panel. The coil holds at 24 V DC nominal and drops out above 0.10 Uc (about 2.4 V); pick-up range is 0.8 to 1.15 Uc (19.2 to 27.6 V DC). Heat dissipation from the control circuit is 3 W, which matters when you're packing several contactors in a small enclosure — factor that into your thermal budget. The AC-3e rating (9 A) is the one that governs motor switching — it's tested for making and breaking locked-rotor currents typical of squirrel-cage induction motors. The AC-1 rating (20 A at 122 °F) covers resistive loads like heaters. For motor sizing: this contactor handles up to 4 kW at 380–415 V AC, 4 kW at 440–500 V, and 4 kW at 660–690 V, all at 50/60 Hz. On 220–230 V it's good for 2.2 kW. Horsepower ratings under UL/CSA go up to 5 hp at 460–480 V and 575–600 V. The auxiliary contact is 1 NC — one normally-closed contact for feedback or interlock. If you need more auxiliaries, the TeSys K family accepts add-on contact blocks that clip onto the front. The power and control terminals accept screw clamp, spring clamp, or Faston connectors (0.25 in and 0.1 in), giving flexibility for different wiring practices. Environmental limits: operates from -13 to 122 °F (-25 to 50 °C), stores from -58 to 176 °F (-50 to 80 °C). Altitude derating starts above 2000 m. Shock resistance is 10 gn closed, 6 gn open; vibration resistance is 4 gn closed, 2 gn open over 5–300 Hz. That's enough for most industrial machinery but check if your application involves sustained high-G vibration. The reversing contactor is a ready-assembled unit — two contactors with a mechanical interlock, pre-mounted on a common base. Dimensions: 3.5 in (90 mm) wide, 2.3 in (58 mm) tall, 2.2 in (57 mm) deep. The IP2X finger protection (VDE 0106) means it's safe for open-panel mounting but not for washdown environments — keep it inside an enclosure rated for the actual environment. Certified to EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Fire resistance tested at 1562 °F (850 °C) per IEC 60695-2-1. Protective treatment follows IEC 60068. These are the standards that matter for a global panel — UL and CSA for North America, IEC for Europe and Asia.","metaTitle":"Schneider TeSys K LP2K09015BDTQ Reversing Contactor, 24V DC,","metaDescription":"Active reversing contactor, TeSys K, 3-pole, AC-3/AC-3e, 9A at 440V, 24V DC coil. UL/CSA/IEC. Mechanical interlock. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"2.2 in (57 mm)","Width":"3.5 in (90 mm)","title":"LP2K09015BDTQ","Height":"2.3 in (58 mm)","Category":"22322-CTR,K-LINE,DC,OPEN,REV","Coil type":"DC standard","Standards":"EN/IEC 60947-4-1 GB/T 14048.4 UL 60947-4-1 CSA C22.2 No 60947-4-1 JIS C8201-4-1","description":"Reversing contactor, TeSys K, 3poles, AC-3/AC-3e,440V 9A, coil 24V DC","Assembly style":"Ready assembled","Motor power kW":"2.2 kW 220...230 V AC 50/60 Hz 4 kW 380...415 V AC 50/60 Hz 4 kW 440/500 V AC 50/60 Hz 4 kW 660/690 V AC 50/60 Hz","Coil technology":"Built-in bidirectional peak limiting diode suppressor","Fire resistance":"1562 °F (850 °C) IEC 60695-2-1","lifecycle_stage":"current","Heat dissipation":"3 W for control circuit","Quantity per Set":"Set of 10","Range of Product":"TeSys K","Shock resistance":"10 gn contactor closed 6 gn contactor opened","Device short name":"LP2K","Interlocking type":"Mechanical","Poles description":"3P","Operating altitude":"6561.68 ft (2000 m) without derating","Control circuit type":"DC","Protective treatment":"TCIEC 60068","Utilisation category":"AC-3 AC-3e","Vibration resistance":"2 gn 5...300 Hz contactor opened 4 gn 5...300 Hz contactor closed","Contactor application":"Motor control","Nbr. of units in pkg.":"1","Connections - terminals":"Power circuit screw clamp terminal 1 x 0.002 in² (1.5 mm²)solid Power circuit screw clamp terminal 2 x 0.006 in² (4 mm²)solid Power circuit screw clamp terminal 1 x 0.001 in² (0.75 mm²)flexible without cable end Power circuit screw clamp terminal 2 x 0.006 in² (4 mm²)flexible without cable end Power circuit screw clamp terminal 1 x 0.0005 in² (0.34 mm²)flexible with cable end Power circuit screw clamp terminal 1 x 0.002 in² (1.5 mm²)flexible with cable end Power circuit screw clamp terminal 1 x 0.004 in² (2.5 mm²)flexible with cable end Control circuit screw clamp terminal 1 x 0.002 in² (1.5 mm²)solid Control circuit screw clamp terminal 2 x 0.006 in² (4 mm²)solid Control circuit screw clamp terminal 1 x 0.001 in² (0.75 mm²)flexible without cable end Control circuit screw clamp terminal 2 x 0.006 in² (4 mm²)flexible without cable end Control circuit screw clamp terminal 1 x 0.0005 in² (0.34 mm²)flexible with cable end Control circuit screw clamp terminal 1 x 0.002 in² (1.5 mm²)flexible with cable end Control circuit screw clamp terminal 1 x 0.004 in² (2.5 mm²)flexible with cable end Power circuit spring terminal 1 x 0.001 in² (0.75 mm²)solid Power circuit spring terminal 1 x 0.002 in² (1.5 mm²)solid Power circuit spring terminal 1 x 0.001 in² (0.75 mm²)flexible without cable end Power circuit spring terminal 1 x 0.002 in² (1.5 mm²)flexible without cable end Control circuit spring terminal 1 x 0.001 in² (0.75 mm²)solid Control circuit spring terminal 1 x 0.002 in² (1.5 mm²)solid Control circuit spring terminal 1 x 0.001 in² (0.75 mm²)flexible without cable end Control circuit spring terminal 1 x 0.002 in² (1.5 mm²)flexible without cable end Power circuit Faston connectors 2 x clip 0.1 in (2.8 mm) Power circuit Faston connectors 1 x clip 0.25 in (6.35 mm) Control circuit Faston connectors 2 x clip 0.1 in (2.8 mm) Control circuit Faston connectors 1 x clip 0.25 in (6.35 mm)","IP degree of protection":"IP2X VDE 0106","Pole contact composition":"3 NO","Product or Component Type":"Reversing contactor","Maximum Horse Power Rating":"2 hp 200/208 V AC 60 Hz CSA 2 hp 200/208 V AC 60 Hz UL 3 hp 230/240 V AC 60 Hz CSA 3 hp 230/240 V AC 60 Hz UL 5 hp 460/480 V AC 60 Hz CSA 5 hp 460/480 V AC 60 Hz UL 5 hp 575/600 V AC 60 Hz CSA 5 hp 575/600 V AC 60 Hz UL","Rated operational power in W":"120 W 24 V DC-13 1000000 cycles - control circuit 15 W 24 V DC-13 10000000 cycles - control circuit 55 W 24 V DC-13 3000000 cycles - control circuit","[Uc] control circuit voltage":"24 V DC","Auxiliary contact composition":"1 NC","Control circuit voltage limits":"Drop-out: >= 0.10 Uc (at Operational: 0.8...1.15 Uc (at 10 MOhm for control circuit","[Ie] rated operational current":"Power circuit 20 A AC AC-1 122 °F (50 °C)) Power circuit 9 A AC AC-3e","Ambient Air Temperature for Storage":"-58...176 °F (-50...80 °C)","Ambient Air Temperature for Operation":"-13...122 °F (-25...50 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a15d89e03ba62ffb4f921659ae642f67.pdf","sourceUrl":"https://www.se.com/us/en/product/LP2K09015BDTQ/reversing-contactor-tesys-k-3poles-ac3-ac3e440v-9a-coil-24v-dc/"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"It is a 3-pole reversing contactor rated 9 A in AC-3 (motor switching) at 440 V, with a 24 V DC coil. The AC-1 resistive rating is 20 A at 122 °F. Motor power capacity reaches 4 kW at 380–415 V AC, and UL/CSA horsepower rating goes up to 5 hp at 460–480 V."},{"question":"What compliance documentation does this brand provide for LP2K09015BDTQ?","answer":"The contactor is certified to EN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, and JIS C8201-4-1. Fire resistance is tested at 1562 °F per IEC 60695-2-1, and protective treatment follows IEC 60068."},{"question":"Does this reversing contactor have built-in coil suppression?","answer":"Yes, the coil includes a built-in bidirectional peak-limiting diode suppressor, so no external snubber is needed across the coil."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K09015BDTQ","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K09015BDTQ when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}