{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K0901JD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K0901JD","canonicalUrl":"https://aoctrl.com/schneider/LP2K0901JD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K0901JD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K0901JD, 3P, AC-3/AC-3e 9A at ≤440V, 1NC, 12V DC coil, preassembled with reversing power busbar.","salesMarkdown":"The LP2K0901JD is a TeSys K reversing contactor — a 3-pole unit rated for 9 A in AC-3 and AC-3e duty at voltages up to 440 V, with a 12 V DC coil and one normally-closed auxiliary contact. It ships preassembled with the reversing power busbar, which saves panel-build time on motor-reversing circuits. The utilisation categories cover AC-1 (resistive), AC-3 (squirrel-cage motor starting), AC-3e (high-efficiency motors), and AC-4 (plugging/inching), so it handles both standard and demanding motor control applications. IP20 finger-safe terminals are standard per VDE 0106. The 9 A AC-3 rating at ≤440 V is the headline number for motor switching — it tells you this contactor can start and stop a 3-phase induction motor drawing up to 9 A under full-load conditions. The AC-3e category extends that to premium-efficiency motors, which draw slightly higher inrush. The 12 V DC coil is a specific control voltage; verify your PLC or relay output matches before specifying. The 1 NC auxiliary gives you one normally-closed feedback contact for status monitoring or interlocking. Mechanical robustness specs (15 Gn shocks contactor closed, 4 Gn vibration on Z axis) mean it holds in on high-vibration machinery like conveyors or compressors. The contactor measures 2.3 in high × 3.5 in wide × 2.2 in deep (58 × 90 × 57 mm). The preassembled reversing busbar means the mechanical interlock and power wiring between the two contactors are already in place — you land the line and load connections and wire the coil. Operating altitude is 2000 m without derating; above that, reduce the rated current per IEC 60947.","metaTitle":"Schneider TeSys K LP2K0901JD Reversing Contactor, 9A AC-3, 1","metaDescription":"Obsolete TeSys K LP2K0901JD reversing contactor. 3P, 9A AC-3/AC-3e at ≤440V, 1NC, 12V DC coil. Sourced to order against RFQ. Last-time-buy available via RFQ confirmation.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"2.2 in (57 mm)","Range":"TeSys","Width":"3.5 in (90 mm)","Height":"2.3 in (58 mm)","Category":"22322-CTR,K-LINE,DC,OPEN,REV","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device Application":"Control","Operating altitude":"6561.68 ft (2000 m) without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC IEC 60068 TC DIN 50016","Utilisation category":"AC-1 AC-4 AC-3 AC-3e","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 Shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","IP degree of protection":"IP20 VDE 0106","Product or Component Type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit 690 V AC 50/60 Hz Signalling circuit 10 MOhm for signalling circuit","Ambient Air Temperature for Storage":"-58...176 °F (-50...80 °C)","Ambient Air Temperature for Operation":"-13...122 °F (-25...50 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/8c4d89e39cf2d970b91dbe022aecbc92.pdf","sourceUrl":"https://www.se.com/vn/en/product/LP2K0901JD/reversing-contactortesys-k-3p-ac3-ac3e-440v-9a-1nc-12v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K0901JD/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LP2K0901JD?","answer":"Schneider does not list a direct drop-in successor for this order code. The TeSys K series itself is superseded by the TeSys Deca range, but pin-to-pin compatibility and coil voltage must be verified against your panel layout. For an installed base, securing last-time-buy stock of the LP2K0901JD is the safest path."},{"question":"What are the key ratings for the LP2K0901JD?","answer":"3-pole reversing contactor, 9 A in AC-3/AC-3e at ≤440 V, 12 V DC coil, 1 NC auxiliary contact. Preassembled with reversing power busbar. IP20 finger-safe terminals."},{"question":"What compliance documentation is available for the LP2K0901JD?","answer":"The contactor carries UL 94 V-1 flame retardance and meets NF F 16-101/102 for rail fire behaviour. Protective treatment follows IEC 60068 and DIN 50016. Standard Schneider documentation (datasheet, certificate of conformity) is available on request."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K0901JD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K0901JD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}