{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K0901LD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K0901LD","canonicalUrl":"https://aoctrl.com/schneider/LP2K0901LD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K0901LD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 9 A, 1 NC, 200 V DC coil, IP20, preassembled with reversing power busbar.","salesMarkdown":"It is preassembled with the reversing power busbar, so it arrives ready to wire into a motor-reversing circuit without sourcing separate interlock hardware. IP20 finger-safe terminals (VDE 0106) mean it mounts inside a control cabinet; the enclosure provides the environmental seal. The 200 V DC coil is a less common voltage — verify your control transformer or DC supply matches before committing the BOM line. ## Integration Notes for a Reversing Contactor The LP2K0901LD is a 3-pole reversing contactor with mechanical and electrical interlock built into the preassembled busbar. This eliminates the risk of both contactors closing simultaneously — a direct short across the supply if they do. The single NC auxiliary (1 NC) is typically wired into the opposite contactor's coil circuit as an additional electrical interlock — standard practice for reversing starters. The 200 V DC coil draws a holding current that is lower than the pick-up surge. If your control supply is a DC bus with other loads, confirm the inrush does not pull the bus below the dropout threshold of other devices on the same rail.","metaTitle":"Schneider TeSys K LP2K0901LD Reversing Contactor, 3P, 9A AC-","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 9A at 440V, 1 NC, 200VDC coil. IP20. Sourced to order via RFQ. Check for replacement options.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1 AC-4 AC-3","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1a97d9fbba46b680d02995ab6594c326.pdf","sourceUrl":"https://www.se.com/mk/en/product/LP2K0901LD/tesys-k-reversing-contactor-3p-ac3-440-v-9-a-1-nc-200-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K0901LD/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the LP2K0901LD?","answer":"It is a 3-pole reversing contactor rated AC-3 at 9 A up to 440 V, with a 200 V DC coil and one normally closed auxiliary contact. It is preassembled with the reversing power busbar and carries IP20 finger-safe protection."},{"question":"What is the physical size of the LP2K0901LD?","answer":"The contactor is 90 mm wide, 58 mm high, and 57 mm deep. It mounts on a standard 35 mm DIN rail."},{"question":"What approvals does the LP2K0901LD carry?","answer":"The evidence lists IP20 protection per VDE 0106, flame retardance V1 per UL 94, and compliance with IEC 60068 for mechanical robustness (shock and vibration). It also meets NF F 16-101 and NF F 16-102 for fire behavior and DIN 50016 for protective treatment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K0901LD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K0901LD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}