{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K09103BD3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K09103BD3","canonicalUrl":"https://aoctrl.com/schneider/LP2K09103BD3","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K09103BD3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K09103BD3, 3P, AC-3 <=440 V 9 A, 1 NO, 24 V DC coil, IP20.","salesMarkdown":"The LP2K09103BD3 is a TeSys K reversing contactor from Schneider Electric — a 3-pole device preassembled with a reversing power busbar, designed for control of small three-phase motors up to 9 A in AC-3 duty at 440 V. Dimensions are 90 mm wide by 58 mm high by 57 mm deep — a compact block that fits standard DIN-rail enclosures. IP20 protection (fingersafe terminals) means it is intended for inside a panel, not exposed to washdown. Flame retardance is V-1 per UL 94, which meets most industrial panel fire-safety requirements. ## Mechanical robustness and approvals Rated for 15 Gn shock (closed contacts) on Z axis per IEC 60068-2-27, and vibration up to 4 Gn closed — figures that confirm it survives transport and moderate machine vibration. Protective treatment conforms to IEC 60068 and DIN 50016 for humid/aggressive environments. The utilisation categories cover AC-1 (resistive), AC-3 (motor start/run), and AC-4 (plugging/inching), so it can handle reversing duty with frequent starts.","metaTitle":"TeSys K LP2K09103BD3 Reversing Contactor, AC-3 9A, 24V DC Co","metaDescription":"TeSys K LP2K09103BD3 reversing contactor, 3P, AC-3 <=440V 9A, 1 NO, 24V DC coil. Obsolete — sourced to order against RFQ. IP20, V-0 flame retardance.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/296541872c0f26348f6a3204fb5e4135.pdf","sourceUrl":"https://www.se.com/vn/en/product/LP2K09103BD3/tesys-k-reversing-contactor-3p-ac3-440-v-9-a-1-no-24-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K09103BD3/alternatives.json"},"ai":{"faq":[{"question":"What is the closest pin-compatible alternative?","answer":"There is no official successor order code from the manufacturer. For a new design, a current TeSys K or TeSys Deca reversing contactor with matching pole count, coil voltage, and AC-3 current rating would be the functional path, but physical footprint and terminal layout must be verified against the panel cutout."},{"question":"What is the depth of this contactor?","answer":"The listed depth is 57 mm."},{"question":"What compliance documentation is available?","answer":"The part carries V-1 flame retardance per UL 94, IP20 per VDE 0106, and protective treatment per IEC 60068 and DIN 50016. RoHS/REACH compliance is standard for the TeSys K range but not explicitly listed in this record."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K09103BD3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K09103BD3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}