{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K12004ND3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K12004ND3","canonicalUrl":"https://aoctrl.com/schneider/LP2K12004ND3","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K12004ND3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K series, LP2K12004ND3 changeover contactor, 4 poles, 60 V DC coil, preassembled with reversing power busbar, IP20.","salesMarkdown":"It switches resistive loads (AC-1 utilisation category) across four poles, with a 60 V DC coil that includes a built-in bidirectional peak limiting diode suppressor — no external flyback diode needed on the coil circuit. The 4-pole configuration gives you two sets of normally-open and normally-closed power contacts for forward/reverse motor control or source transfer switching. Rated insulation voltage (Ui) is 690 V per IEC 60947-4-1 and 600 V per UL 508 / CSA C22.2 No 14, so the contactor is rated for 480 V and 600 V class systems in North America and 690 V class in IEC territories. The 60 V DC control coil holds in at 0.8 to 1.15 Uc (48 to 69 V DC) and drops out between 0.1 and 0.75 Uc (6 to 45 V DC) — this wide dropout margin means it will not nuisance-drop on a sagging 48 V bus, but also that a slow-decay DC supply may hold it closed longer than expected. Mechanical interlocking is built into the reversing assembly, preventing both contactors from closing simultaneously — a standard requirement for reversing starters. Mounts on DIN rail or plate (rail/plate mounting support). Screw-clamp terminals accept 1.5 to 4 mm² solid or 0.75 to 4 mm² flexible (with or without ferrules), torqued to 1.3 N·m. Compliant with IEC 60947, VDE 0660, BS 5424, and NF C 63-110. Flame retardance rated V1 per UL 94, plus meets NF F 16-101/102 for railway fire-smoke-toxicity. Protective treatment TC per IEC 60068 and DIN 50016 for tropical climate resistance.","metaTitle":"Schneider Electric LP2K12004ND3 TeSys K Changeover Contactor","metaDescription":"Schneider Electric LP2K12004ND3 TeSys K changeover contactor, 4 poles, 60 VDC coil, preassembled reversing busbar, IP20, current production stage.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Standards":"VDE 0660 BS 5424 NF C 63-110 IEC 60947","Product name":"TeSys K","Operating time":"30...40 ms coil energisation and NO closing 10 ms coil de-energisation and NO opening","Coil technology":"Built-in bidirectional peak limiting diode suppressor","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"3 W","Mounting support":"Rail Plate","Average impedance":"3 mOhm - Ith 20 A 50 Hz for power circuit","Device short name":"LP2K","Inrush power in W":"3 W (at 20 °C)","Interlocking type":"Mechanical","Poles description":"4P","Tightening torque":"1.3 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Control circuit type":"DC standard","Overvoltage category":"III","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"0.3 Mcycles 20 A AC-1 at Ue <= 440 V","Mechanical durability":"5 Mcycles","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","Associated fuse rating":"25 A gG at 25 A aM for power circuit","Maximum operating rate":"3600 cyc/h","Connections - terminals":"Screw clamp terminals 1 cable(s) 1.5...4 mm²solid Screw clamp terminals 1 cable(s) 0.75...4 mm²flexible without cable end Screw clamp terminals 1 cable(s) 0.34...2.5 mm²flexible with cable end Screw clamp terminals 2 cable(s) 1.5...4 mm²solid Screw clamp terminals 2 cable(s) 0.75...4 mm²flexible without cable end Screw clamp terminals 2 cable(s) 0.34...1.5 mm²flexible with cable end","IP degree of protection":"IP20 conforming to VDE 0106","Rated breaking capacity":"110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1","Product or component type":"Changeover contactor","Irms rated making capacity":"144 A AC for power circuit conforming to NF C 63-110 144 A AC for power circuit conforming to IEC 60947","[Uc] control circuit voltage":"60 V DC","[Ui] rated insulation voltage":"Power circuit: 600 V conforming to UL 508 Power circuit: 690 V conforming to IEC 60947-4-1 Power circuit: 600 V conforming to CSA C22.2 No 14","Control circuit voltage limits":"Operational: 0.8...1.15 Uc (at Drop-out: 0.1...0.75 Uc (at <50 °C)","Hold-in power consumption in W":"3 W at 20 °C","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"20 A (at 16 A (at <70 °C) at 690 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"115 A 50 °C - 1 s for power circuit 105 A 50 °C - 5 s for power circuit 100 A 50 °C - 10 s for power circuit 75 A 50 °C - 30 s for power circuit 55 A 50 °C - 1 min for power circuit 50 A 50 °C - 3 min for power circuit 25 A 50 °C - >= 15 min for power circuit","[Ith] conventional free air thermal current":"20 A (at 50 °C) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/cabfce2a05db6f41ffe08d916f174602.pdf","sourceUrl":"https://www.se.com/ie/en/product/LP2K12004ND3/tesys-k-changeover-contactor-4p-ac1-440-v-20-a-60-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K12004ND3/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative in the TeSys K family?","answer":"Within the TeSys K range, the LP2K series covers reversing contactors preassembled with busbars. The LP2K12004ND3 is the 4-pole, 60 V DC variant. A 3-pole version (LP2K09004ND3) exists for applications not requiring the fourth pole, but pin-compatibility depends on your wiring scheme — the 4-pole adds an extra set of terminals per side."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries IEC 60947, VDE 0660, BS 5424, and NF C 63-110 standards. Flame retardance is V1 per UL 94. It also meets NF F 16-101/102 for railway applications and has protective treatment per IEC 60068 and DIN 50016 for tropical environments. UL and CSA listings are confirmed for the insulation voltage ratings (600 V per UL 508, 600 V per CSA C22.2 No 14)."},{"question":"What is the depth of this component?","answer":"The LP2K12004ND3 has a depth of 57 mm, with a width of 90 mm and height of 58 mm."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K12004ND3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K12004ND3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}