{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K12015ED","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K12015ED","canonicalUrl":"https://aoctrl.com/schneider/LP2K12015ED","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K12015ED","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NC, 48 V DC coil, IP20.","salesMarkdown":"The 48 V DC coil keeps the control circuit separate from the power side, which simplifies PLC output wiring. AC-1 (resistive) and AC-4 (plugging/inching) are also listed, so this contactor can handle both resistive heater loads and the high-stress reversing duty where the motor is switched while still spinning. IP20 protection (finger-safe terminals) means it's intended for enclosure mounting — not washdown or outdoor exposure. The 57 mm depth and 90 mm width fit a standard DIN-rail footprint, and the preassembled reversing busbar saves panel space versus two separate contactors with a mechanical interlock kit. ## Where it goes in a panel Mounts on DIN rail inside a control cabinet. The 48 V DC coil draws from a power supply or PLC output card; verify the coil suppression matches the driver (free-wheel diode polarity matters for DC outputs). The IP20 housing keeps fingers off live terminals, but the contactor itself needs the enclosure's IP rating for the overall assembly.","metaTitle":"Schneider LP2K12015ED TeSys K reversing contactor, 3P, 12 A","metaDescription":"Schneider TeSys K LP2K12015ED reversing contactor, 3P, AC-3 12 A at 440 V, 48 V DC coil, IP20, active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K12015ED","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 48 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-1 AC-3","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9899a523da576b1886a90553a2a74acf.pdf","sourceUrl":"https://www.se.com/in/en/product/LP2K12015ED/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-48-v-dc-coil/"},"ai":{"faq":[{"question":"What is the closest alternative within the TeSys K family?","answer":"The LP2K12015ED is the reversing contactor variant with a 48 V DC coil and 1 NC auxiliary. A direct sibling would share the same 3-pole reversing busbar and AC-3 rating but differ by coil voltage — for example, a 24 V DC or 230 V AC coil version. The mechanical footprint and busbar arrangement are identical, so swapping coil voltage is the main decision point."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K12015ED","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K12015ED when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}