{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K12017BD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K12017BD","canonicalUrl":"https://aoctrl.com/schneider/LP2K12017BD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K12017BD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K12017BD, 3 poles, AC-3 ≤ 440 V 12 A, 1 NC auxiliary, 24 V DC coil, preassembled with reversing power busbar.","salesMarkdown":"The Schneider Electric TeSys K LP2K12017BD is a 3-pole reversing contactor rated for AC-3 duty at 12 A up to 440 V, with a 24 V DC coil and one normally-closed auxiliary contact. The 24 V DC coil means it drops into a 24 VDC control circuit common in modern panels; verify your control transformer and power supply can deliver the inrush without sag. The 3 NO power poles and 1 NC auxiliary give you one feedback contact for status monitoring or interlocking. DIN-rail-mountable reversing contactor for motor control panels or conveyor reversing stations. Mechanical robustness is specified for shock and vibration per IEC 60068-2-27 and IEC 60068-2-6, with the contactor closed handling 15 Gn on Z axis for 11 ms and vibration up to 4 Gn at 5–300 Hz. That's enough for most industrial machinery but not for high-shock applications like press lines without additional isolation. V1 flame retardance per UL 94, plus NF F 16-101 and NF F 16-102 compliance. Protective treatment conforms to IEC 60068 and DIN 50016.","metaTitle":"Schneider TeSys K LP2K12017BD reversing contactor, 3P, 12 A","metaDescription":"Schneider Electric TeSys K LP2K12017BD reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 24 V DC coil. Active production. Preassembled with reversing busbar. IP20. Spec to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K12017BD","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 24 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4 AC-1","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b5bdd925359cd7ad18ea93f8c5e2cec5.pdf","sourceUrl":"https://www.se.com/ie/en/product/LP2K12017BD/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-24-v-dc-coil/"},"ai":{"faq":[{"question":"What are the key ratings that decide fit for this reversing contactor?","answer":"The critical rating is AC-3 ≤ 440 V at 12 A — that's the motor-switching current for starting and stopping induction motors under load. The 24 V DC coil voltage must match your control circuit. The contactor has 3 NO power poles and 1 NC auxiliary contact. Dimensions are 90 mm wide × 58 mm high × 57 mm deep for DIN-rail mounting."},{"question":"Does this contactor come with the reversing busbar?","answer":"Yes, the LP2K12017BD is described as preassembled with a reversing power busbar, so it's ready to wire into a reversing starter circuit without ordering a separate busbar kit."},{"question":"What compliance documentation is available for the LP2K12017BD?","answer":"The contactor carries a V1 flame retardance rating per UL 94 and complies with NF F 16-101 and NF F 16-102 for railway fire-smoke-toxicity. Protective treatment conforms to IEC 60068 and DIN 50016. The record does not list RoHS or REACH declarations explicitly, so verify with your Schneider documentation package for your specific compliance needs."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K12017BD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K12017BD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}