{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K12017JD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K12017JD","canonicalUrl":"https://aoctrl.com/schneider/LP2K12017JD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K12017JD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NC, 12 V DC coil, IP20.","salesMarkdown":"Rated AC-3 at 12 A up to 440 V, it switches motor loads in that current band; the AC-1 rating covers resistive loads at the same current level. Vibration withstand of 4 Gn closed, 2 Gn open per IEC 60068-2-6, and shock ratings (15 Gn closed on Z axis) mean it holds in on high-vibration lines like conveyor drives or compressor skids. Flame retardance rated V1 per UL 94, with additional compliance to NF F 16-101 and NF F 16-102 (railway fire behaviour). Protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance. Utilisation categories AC-1, AC-3, and AC-4 cover resistive, motor starting, and plugging/inching duty respectively.","metaTitle":"Schneider TeSys K LP2K12017JD reversing contactor, 12 A AC-3","metaDescription":"TeSys K reversing contactor, 3P, AC-3 12 A at 440 V, 1 NC, 12 V DC coil, IP20. Active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K12017JD","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 12 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d3ea5fbb53b7f193a342bb01c746d945.pdf","sourceUrl":"https://www.se.com/mk/en/product/LP2K12017JD/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-12-v-dc-coil/"},"ai":{"faq":[{"question":"What is the closest alternative to LP2K12017JD in the same family?","answer":"Within the TeSys K series, the LP2K12017JD is the reversing contactor variant with a 12 V DC coil. The standard non-reversing contactor with the same coil voltage is the LC1K12017JD; the reversing busbar and mechanical interlock are pre-integrated on the LP2K, so swapping to two LC1Ks plus external interlocks would take more panel space and wiring. If the coil voltage can change, the LP2K12017JD has siblings with 24 V DC, 48 V DC, and 110 V AC coils — verify your control voltage before substituting."},{"question":"What is the depth of the LP2K12017JD?","answer":"57 mm depth (body only, excluding coil terminals). Combined with 90 mm width and 58 mm height, it fits a standard 200 mm deep enclosure with room for wiring."},{"question":"What compliance documentation does Schneider provide for this part?","answer":"The part carries UL 94 V1 flame rating, IEC 60068 environmental testing, and NF F 16-101/102 railway fire compliance. Standard Schneider documentation includes the datasheet (with wiring diagrams), a user manual, and a declaration of conformity covering the CE mark. RoHS and REACH declarations are available through the Schneider portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K12017JD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K12017JD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}