{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K1201ED3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K1201ED3","canonicalUrl":"https://aoctrl.com/schneider/LP2K1201ED3","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K1201ED3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NC, 48 V DC coil, IP20, preassembled with reversing power busbar.","salesMarkdown":"Its coil pulls in on 48 V DC, and the contactor is rated for AC-3 duty at 12 A up to 440 V, which means it directly switches a reversing motor load — say a conveyor drive or a pump — up to that current without external interlocking relays. The same contactor also carries AC-1 and AC-4 utilisation categories, covering resistive loads and plugging/inching respectively, so it is not limited to standard start-run cycles. Ambient operating range is -25 to 50 °C, and it derates above 2000 m altitude — fine for most plant-floor applications provided the panel stays within those limits. ## Integration notes The contactor measures 90 mm wide by 58 mm high by 57 mm deep — a compact footprint that fits standard DIN-rail or panel-mount layouts typical of TeSys K installations. The preassembled reversing busbar saves wiring time and reduces the chance of phase-reversal errors during commissioning. Flame retardance meets V1 per UL 94, so it satisfies the flammability requirements for most industrial control panels.","metaTitle":"Schneider Electric LP2K1201ED3 TeSys K Reversing Contactor,","metaDescription":"TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NC, 48 V DC coil. Obsolete — sourced to order against RFQ. LP2K1201ED3 from Schneider Electric.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/473f667a26ce8dd1891ecd0547e27671.pdf","sourceUrl":"https://www.se.com/mk/en/product/LP2K1201ED3/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-48-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K1201ED3/alternatives.json"},"ai":{"faq":[{"question":"What are the key electrical ratings of the LP2K1201ED3?","answer":"It is a 3-pole reversing contactor with a 48 V DC coil, rated 12 A in AC-3 utilisation category at up to 440 V, with a maximum operational voltage of 690 V AC on the power circuit. It also covers AC-1 (resistive) and AC-4 (plugging/inching) categories."},{"question":"What is the closest alternative to the LP2K1201ED3?","answer":"No official successor or pin-compatible replacement is listed in the lifecycle record. A parametric substitute from the TeSys K or TeSys D range would need to match the 48 V DC coil voltage, 3-pole reversing configuration, and AC-3 current rating — but the exact fit must be verified against the panel wiring and mounting dimensions."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K1201ED3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K1201ED3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}