{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K1201GD3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K1201GD3","canonicalUrl":"https://aoctrl.com/schneider/LP2K1201GD3","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K1201GD3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K1201GD3, 3P, AC-3 <= 440 V 12 A, 1 NC, 125 V DC coil, preassembled with reversing power busbar.","salesMarkdown":"## Ratings and application The LP2K1201GD3 is a TeSys K reversing contactor, 3P, rated AC-3 at 12 A up to 440 V, with a 125 V DC coil and one NC auxiliary contact. The AC-3 rating governs motor switching under full load — the 12 A figure is the current it can make and break across the rated voltage range, so it matches a 3-pole reversing starter for a motor drawing up to that line current. Preassembled with the reversing power busbar, so the mechanical interlock and bus connections are factory-set — no field assembly of the reversing pair. Utilisation categories cover AC-1 (resistive loads), AC-3 (squirrel-cage motors: starting, switching off running motors), and AC-4 (plugging, inching). The AC-4 rating is the harder duty cycle — if the application requires frequent reversing or jogging, that's the rating to size against, not the AC-3 figure. ## Mechanical robustness Rated for 15 Gn shocks on Z axis (contactor closed) and 10 Gn (opened) per IEC 60068-2-27. Vibration resistance: 4 Gn closed, 2 Gn opened across 5-300 Hz per IEC 60068-2-6. These figures matter for applications mounted on machinery or in mobile equipment where shock and vibration are present — the contactor holds its state without chatter under those conditions.","metaTitle":"Schneider TeSys K LP2K1201GD3 Reversing Contactor, 3P, 12A A","metaDescription":"TeSys K reversing contactor LP2K1201GD3, 3P, AC-3 <=440V 12A, 1 NC, 125V DC coil. Active production. IP20. Preassembled reversing busbar. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K1201GD3","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 125 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-1 AC-3","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/94cf9f36ba68cada3d706345309830c9.pdf","sourceUrl":"https://www.se.com/mk/en/product/LP2K1201GD3/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-125-v-dc-coil/"},"ai":{"faq":[{"question":"What is the closest alternative to the LP2K1201GD3 in the TeSys K family?","answer":"Within the TeSys K range, the LP2K series shares the same reversing contactor form factor and coil voltage options. The LP2K1201GD3 is the 12 A AC-3 variant with a 125 V DC coil. A different coil voltage or current rating would be the differentiating factor for a substitute — verify the coil voltage and utilisation category match the application."},{"question":"What is the depth of the LP2K1201GD3?","answer":"Listed depth is 57 mm."},{"question":"What is the range of the LP2K1201GD3?","answer":"It belongs to the TeSys range, specifically the TeSys K product line."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K1201GD3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K1201GD3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}