{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K1201LD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K1201LD","canonicalUrl":"https://aoctrl.com/schneider/LP2K1201LD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K1201LD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 ≤440 V 12 A, 1 NC auxiliary, 200 V DC coil, IP20.","salesMarkdown":"The coil pulls in on 200 V DC, and there's one NC auxiliary contact built in for status feedback or a holding circuit. The AC-3 rating is the one that matters for motor starting — 12 A at 440 V means it'll switch a 5.5 kW motor (roughly 7.5 HP) on a 400 V line without welding the contacts. AC-4 covers inching and plugging if you need it. The 690 V max operational voltage gives headroom for 480 V or 600 V systems, but the AC-3 current drops above 440 V — check the derating curve if you're running at 600 V. The 200 V DC coil is less common than 24 V or 110 V; make sure your control transformer or DC supply is set for that voltage before you spec it in. It's a DIN-rail-mount contactor, 57 mm deep by 90 mm wide by 58 mm tall — fits a standard TS35 rail. The preassembled reversing busbar saves you the headache of cross-wiring two contactors and a mechanical interlock; just land your line and load wires. Ambient range is -25 to 50 °C, so it's fine in a ventilated enclosure on the floor.","metaTitle":"Schneider TeSys K LP2K1201LD Reversing Contactor, 3P, AC-3 1","metaDescription":"TeSys K reversing contactor LP2K1201LD, 3P, AC-3 <=440V 12A, 1NC, 200VDC coil. Active production, IP20. Sourced to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K1201LD","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NC, 200 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4 AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/1bd1f6e0e1c9048babacd0fa8d43605a.pdf","sourceUrl":"https://www.se.com/ie/en/product/LP2K1201LD/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-200-v-dc-coil/"},"ai":{"faq":[{"question":"What are the key ratings I need to know for fit?","answer":"Three-pole reversing contactor, AC-3 rated 12 A at ≤440 V, coil is 200 V DC, one NC auxiliary contact. Dimensions are 57 mm deep, 90 mm wide, 58 mm tall."},{"question":"What compliance documentation does this part carry?","answer":"It has IP20 protection per VDE 0106, flame retardance V1 per UL 94, and protective treatment per IEC 60068 and DIN 50016. The utilisation categories (AC-3, AC-4, AC-1) are per IEC standards."},{"question":"Where is this contactor used?","answer":"It's for motor control and resistive load switching in control panels — specifically reversing applications where you need to change motor direction, like conveyors, small hoists, or pump stations."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K1201LD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K1201LD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}