{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K1201UD3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K1201UD3","canonicalUrl":"https://aoctrl.com/schneider/LP2K1201UD3","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K1201UD3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K1201UD3, 3P, AC-3 12A at 440V, 250V DC coil, 1 NC auxiliary, IP20.","salesMarkdown":"The LP2K1201UD3 is a TeSys K reversing contactor, 3P, AC-3 ≤ 440 V 12 A, 250 V DC coil, 1 NC. The 1 NC auxiliary contact is wired into the opposite-direction coil circuit to block simultaneous engagement, a standard safety practice for reversing starters. AC-3 rating is 12 A at 440 V. AC-4 and AC-1 ratings also apply. IP20 per VDE 0106. The 2000 m altitude rating without derating means it works at most industrial sites; above that, you'd need to factor in air-density effects on arc extinction. Mechanical robustness is specified for shock and vibration per IEC 60068-2-27 and -6 — it holds closed through 15 Gn shocks on the Z axis, and stays open through 10 Gn. That's enough for general industrial machinery but not for extreme off-road or naval applications. There is no official L* successor listed in the evidence, so a direct drop-in replacement isn't confirmed. If you're designing a new panel or replacing a failed unit, the practical move is to cross-reference the TeSys K family for a current-production reversing contactor with the same coil voltage (250 V DC), pole count (3P), and AC-3 rating (12 A). The physical footprint and mounting pattern of the TeSys K series are consistent, so a newer TeSys K variant is the first place to look. V1 flame retardance per UL 94 and NF F 16-101/102. Protective treatment per IEC 60068 and DIN 50016. IP20 per VDE 0106.","metaTitle":"Schneider TeSys K LP2K1201UD3 Reversing Contactor, 3P, 12A A","metaDescription":"TeSys K reversing contactor LP2K1201UD3, 3P, AC-3 12A at 440V, 250V DC coil, 1 NC. Obsolete — sourced to order against RFQ. IP20, V1 flame retardance.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4 AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/27ff32d6cd6e82d05afcbfaa5c2bc1a4.pdf","sourceUrl":"https://www.se.com/mk/en/product/LP2K1201UD3/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-nc-250-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K1201UD3/alternatives.json"},"ai":{"faq":[{"question":"What are the key specifications of the LP2K1201UD3?","answer":"It is a 3-pole reversing contactor rated AC-3 12 A at 440 V, with a 250 V DC coil and 1 NC auxiliary contact. It handles AC-4 and AC-1 loads, operates on power circuits up to 690 V AC, and carries IP20 finger-safe protection. Dimensions are 90 mm wide, 58 mm high, 57 mm deep."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K1201UD3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K1201UD3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}