{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K12103ED","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K12103ED","canonicalUrl":"https://aoctrl.com/schneider/LP2K12103ED","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K12103ED","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K12103ED, 3P, AC-3 ≤440 V 12 A, 1 NO, 48 V DC coil, IP20.","salesMarkdown":"Rated AC-3 at 12 A up to 440 V, it handles reversing duty on small three-phase motors. The 48 V DC coil keeps control-circuit isolation clean. This part is marked obsolete by Schneider Electric. The TeSys K family is mature; if you are qualifying a replacement, the closest functional fit will be a current TeSys Deca or TeSys F reversing contactor with matching coil voltage and pole count, but pinout and mounting dimensions differ — verify the mechanical interface before committing a panel revision. AC-3 means it makes and breaks motor inrush (typically 6–8× FLA) and interrupts the stalled-rotor current. The 48 V DC coil draws roughly 0.2 A steady-state; verify your control transformer or power supply can deliver the inrush peak (about 4× holding current for 50 ms). IP20 means finger-safe terminals but no protection against water ingress — mount inside a panel rated for the environment. The 57 mm depth fits standard 45 mm DIN-rail enclosures with clearance for wiring ducts. Altitude derating kicks in above 2000 m — no change needed for most sites. Vibration resistance: 4 Gn closed, 2 Gn open across 5–300 Hz. Shock: 15 Gn closed on Z axis, 10 Gn open. Flame retardance meets UL 94 V-1 and NF F 16-101/102, which covers rail and industrial panel fire-safety requirements. The protective treatment (TC per IEC 60068 and DIN 50016) indicates basic corrosion resistance for indoor controlled environments.","metaTitle":"Schneider Electric LP2K12103ED TeSys K Reversing Contactor,","metaDescription":"Obsolete TeSys K reversing contactor LP2K12103ED, 3P, AC-3 12 A at 440 V, 48 V DC coil. Sourced to order against RFQ. IP20, UL 94 V-1.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1 AC-4 AC-3","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a45e496c53590baa32ed0fabaefb4696.pdf","sourceUrl":"https://www.se.com/ie/en/product/LP2K12103ED/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-48-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K12103ED/alternatives.json"},"ai":{"faq":[{"question":"What are the key electrical ratings?","answer":"AC-3 motor-switching current: 12 A at ≤440 V. Coil: 48 V DC. Rated operational voltage: 690 V AC 50/60 Hz on the power circuit. Three normally-open power poles."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K12103ED","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K12103ED when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}