{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K12107BD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K12107BD","canonicalUrl":"https://aoctrl.com/schneider/LP2K12107BD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K12107BD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K12107BD, 3P, AC-3 ≤440 V 12 A, 1 NO, 24 V DC coil, preassembled with reversing power busbar.","salesMarkdown":"Rated AC-3 at 12 A up to 440 V, it handles motor starting. The 24 V DC coil suits PLC outputs. The utilisation categories cover AC-3 (squirrel-cage motor starting), AC-4 (inching/plugging), and AC-1 (resistive loads), so it fits both motor and heater applications. IP20 finger-safe terminals suit enclosed panel mounting — no exposed live parts above the DIN-rail profile. Mechanical robustness specs show the contactor withstands 15 Gn shocks when closed and 10 Gn when open — relevant for mobile or high-vibration installations like genset trailers or conveyor transfer points. Vibration resistance at 4 Gn closed, 2 Gn open covers most industrial panel environments. The preassembled reversing busbar saves panel space. IP20 means no additional finger guards needed. Flame retardance meets UL 94 V1 and NF F 16-101/102, so it passes rail and building-material fire-safety requirements. Protective treatment conforms to IEC 60068 and DIN 50016 for corrosion resistance in mildly aggressive atmospheres.","metaTitle":"Schneider TeSys K LP2K12107BD Reversing Contactor, 12A AC-3,","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 ≤440V 12A, 1 NO, 24 V DC coil. Sourced to order against RFQ. IP20, 690V rated.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-1 AC-3","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/33e35cb0092f45939854243bd3a0e6d2.pdf","sourceUrl":"https://www.se.com/ie/en/product/LP2K12107BD/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-24-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K12107BD/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LP2K12107BD?","answer":"Schneider does not list a direct drop-in successor in the TeSys K range. For a new design, consider the TeSys D range (e.g., LC1D12BD) with a separate mechanical interlock — but verify the footprint and busbar arrangement differ. For an existing panel, source the LP2K12107BD through the RFQ process."},{"question":"What are the key ratings for this contactor?","answer":"AC-3 motor-switching current: 12 A at ≤440 V. Coil: 24 V DC. Rated operational voltage: 690 V AC 50/60 Hz. Three normally-open power poles. IP20 protection."},{"question":"What compliance documentation is available?","answer":"The part carries UL 94 V1 flame retardance, NF F 16-101/102 railway fire compliance, and IEC 60068 environmental testing. Specific RoHS/REACH declarations are available on request with the RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K12107BD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K12107BD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}