{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K12107JD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K12107JD","canonicalUrl":"https://aoctrl.com/schneider/LP2K12107JD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K12107JD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 12 A at 440 V, 12 V DC coil, preassembled with reversing busbar, IP20.","salesMarkdown":"The Schneider Electric LP2K12107JD is a TeSys K reversing contactor — a 3-pole device rated AC-3 at 12 A up to 440 V, with a 12 V DC coil. It ships preassembled with the reversing power busbar, which means it arrives as a single unit ready to wire into a motor-reversing circuit without sourcing separate busbar hardware. The AC-3 rating covers squirrel-cage motor starting and switching off under load, so this contactor handles reversing applications like conveyor drives, hoist motors, or pump direction changes where the load is inductive and the contacts must break the motor current. The preassembled busbar saves one wiring step during cabinet build. The 12 V DC coil draws from a control supply common in 24 V DC systems via a step-down or dedicated supply; verify coil inrush and hold current against your power budget. ## Approvals and environmental specs Flame retardance meets V1 per UL 94 and NF F 16-101/102, which is relevant for rail and industrial control panel compliance. Altitude rating is 2000 m without derating. Mechanical robustness is specified per IEC 60068-2-27 and IEC 60068-2-6: the contactor withstands 15 Gn shocks for 11 ms when closed, and 4 Gn vibrations from 5 to 300 Hz when closed — useful for applications on vibrating machinery or mobile equipment.","metaTitle":"Schneider TeSys K LP2K12107JD Reversing Contactor, 3P, AC-3","metaDescription":"Active-production TeSys K reversing contactor, 3P, AC-3 12 A at 440 V, 12 V DC coil, preassembled with reversing busbar, IP20. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K12107JD","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 12 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4 AC-1","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2f54db08ca0c6ffa475ce52ba5150119.pdf","sourceUrl":"https://www.se.com/ie/en/product/LP2K12107JD/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-12-v-dc-coil/"},"ai":{"faq":[{"question":"What is the closest alternative to LP2K12107JD in the TeSys K family?","answer":"Within the same TeSys K reversing contactor family, the key variant difference is coil voltage. The LP2K12107JD is the 12 V DC coil version; a sibling with a 24 V DC coil (e.g., LP2K12107JDW) or 48 V DC coil exists. The AC-3 current rating and busbar preassembly are identical across the coil-voltage variants. Choose based on your control supply voltage."},{"question":"What is the depth of LP2K12107JD?","answer":"The depth is 57 mm."},{"question":"What compliance documentation does Schneider provide for LP2K12107JD?","answer":"The part carries IP20 per VDE 0106, flame retardance V1 per UL 94, and shock/vibration ratings per IEC 60068-2-27 and IEC 60068-2-6. Standard Schneider declarations for RoHS, REACH, and CE are available through their documentation portal. No specific UL or CSA listing number is on this evidence record, but the UL 94 flame class indicates UL-recognized materials."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K12107JD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K12107JD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}