{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K1210CD3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K1210CD3","canonicalUrl":"https://aoctrl.com/schneider/LP2K1210CD3","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K1210CD3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K1210CD3, 3P, AC-3 ≤440 V 12 A, 1 NO auxiliary, 36 V DC coil, preassembled with reversing power busbar.","salesMarkdown":"The LP2K1210CD3 is a TeSys K reversing contactor from Schneider Electric — a 3-pole unit rated AC-3 at 12 A up to 440 V, with a 36 V DC coil and one normally-open auxiliary contact. It ships preassembled with the reversing power busbar, so you don't need to source and fit the interlock kit separately; it's ready to drop into a panel and wire up for motor reversing duty. The AC-3 rating of 12 A at 440 V is the motor-switching current — that's the number that decides fit for a reversing starter on a 3-phase induction motor up to about 5.5 kW at 400 V. The AC-1 rating (resistive load) will be higher, but for motor control, AC-3 is the one that governs contactor life. The 36 V DC coil means it pulls in cleanly on a standard control transformer or battery-backed DC supply; hold-in power is low enough that a small PLC relay can drive it directly. ## Where you'll find it This is a panel-mount reversing contactor for motor control centres, conveyor drives, pump reversing, and any application where you need to swap motor rotation without a separate mechanical interlock. The IP20 finger-safe enclosure (per VDE 0106) means it's suitable for enclosed panels where personnel might reach inside — no extra shrouding required for basic touch protection.","metaTitle":"Schneider TeSys K LP2K1210CD3 reversing contactor, 3P AC-3 1","metaDescription":"Active-production TeSys K reversing contactor, 3P, AC-3 12A at 440V, 36V DC coil, preassembled busbar, IP20. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K1210CD3","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 36 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-4 AC-1 AC-3","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c0819eda33988121d74bda4851b4e980.pdf","sourceUrl":"https://www.se.com/in/en/product/LP2K1210CD3/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-36-v-dc-coil/"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"It's a 3-pole reversing contactor rated AC-3 at 12 A up to 440 V, with a 36 V DC coil and one NO auxiliary contact. It handles motor loads up to that current and voltage, and the preassembled reversing busbar means no separate interlock kit is needed."},{"question":"What compliance documentation is available for the LP2K1210CD3?","answer":"The contactor carries V1 flame retardance per UL 94, IP20 finger-safe protection per VDE 0106, and shock/vibration ratings per IEC 60068-2-27 and IEC 60068-2-6. It also complies with NF F 16-101 and NF F 16-102 for rail fire safety. Standard Schneider documentation includes the datasheet, installation manual, and RoHS/REACH declarations available through their support portal."},{"question":"What is the physical size of this contactor?","answer":"The LP2K1210CD3 measures 90 mm wide, 58 mm high, and 57 mm deep — a compact footprint for a reversing contactor with integrated busbar."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K1210CD3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K1210CD3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}