{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K1210KD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K1210KD","canonicalUrl":"https://aoctrl.com/schneider/LP2K1210KD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K1210KD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 100 V DC coil, IP20.","salesMarkdown":"Rated 12 A in AC-3 duty at up to 440 V, it handles the full-voltage starting and stopping of a three-phase induction motor in that current class; the 100 V DC coil means it pulls in on a 100 VDC control signal, common in DC-switched panels or battery-backed control circuits. The single normally-open auxiliary contact gives you one feedback or interlock signal. This is a panel-mount reversing contactor sized for DIN-rail or screw-mount installation inside an IP20 enclosure. The 57 mm depth and 90 mm width keep it compact for a reversing pair — the busbar is already integrated, so you save the space a separate reversing kit would eat. IP20 (VDE 0106) means finger-safe terminals but no washdown tolerance; keep it inside a cabinet. ## Ratings that matter for the buyer AC-4 covers plugging and inching (higher electrical wear), and AC-1 covers resistive loads. The 100 V DC coil is less common than 24 VDC or 110 VAC; verify your control supply matches before committing the BOM line. ## Mechanical and environmental robustness Rated to withstand 15 Gn shocks on Z axis (contactor closed) and 10 Gn (opened), per IEC 60068-2-27. Vibration resistance is 4 Gn closed, 2 Gn opened across 5-300 Hz. Flame retardance meets V1 per UL 94 and NF F 16-101/102. Protective treatment conforms to IEC 60068 and DIN 50016 for damp-heat and corrosive environments.","metaTitle":"TeSys K LP2K1210KD Reversing Contactor, 12 A AC-3, 100 V DC","metaDescription":"TeSys K LP2K1210KD reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 100 V DC coil. Active production. IP20. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K1210KD","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 100 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4 AC-1","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e1c113655bcecfbaef56c8c48a8fb9e1.pdf","sourceUrl":"https://www.se.com/mk/en/product/LP2K1210KD/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-100-v-dc-coil/"},"ai":{"faq":[{"question":"What are the key ratings for this reversing contactor?","answer":"The LP2K1210KD is rated 12 A in AC-3 duty at <= 440 V, with a 100 V DC coil. It has 3 normally-open power poles and 1 normally-open auxiliary contact. The utilisation categories cover AC-3 (motor starting), AC-4 (plugging/inching), and AC-1 (resistive loads)."},{"question":"What is the closest alternative to the LP2K1210KD in the TeSys K family?","answer":"Within the TeSys K range, the closest functional alternative would be a reversing contactor with the same 3-pole, 12 A AC-3 rating but a different coil voltage — for example, the LP2K1210BW (24 VAC coil) or LP2K1210BD (24 VDC coil). The pinout and mounting footprint are identical; only the coil voltage changes. Verify your control circuit voltage before substituting."},{"question":"What compliance documentation is available for the LP2K1210KD?","answer":"The contactor carries IP20 finger-safe protection per VDE 0106, flame retardance V1 per UL 94, and protective treatment conforming to IEC 60068 and DIN 50016. It is rated for operation up to 2000 m altitude without derating. Standard Schneider Electric declarations (RoHS, REACH, CE) apply to the TeSys K series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K1210KD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K1210KD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}