{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K1210KD3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K1210KD3","canonicalUrl":"https://aoctrl.com/schneider/LP2K1210KD3","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K1210KD3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K1210KD3, 3P, AC-3 12 A at 440 V, 100 V DC coil, preassembled with reversing busbar.","salesMarkdown":"The 100 V DC coil means it pulls in on a standard DC control supply; the IP20 finger-safe enclosure (VDE 0106) suits it for enclosed panel mounting where operators reach inside. The AC-3 rating of 12 A at 440 V is the motor-switching current — it covers starting and plugging duty for three-phase induction motors up to roughly 5.5 kW at 400 V. AC-4 rating (inching/plugging) will be lower, so if your application involves frequent reversing under load, check the AC-4 curve. The 100 V DC coil is a specific control voltage — not 24 V or 110 V AC — so verify your control transformer or power supply delivers 100 V DC nominal. The contactor's 57 mm depth and 90 mm width fit a standard DIN-rail footprint, but the preassembled busbar adds a little length; plan for that in the enclosure layout. ## Where it goes and what it connects to The preassembled reversing busbar links the two contactor halves internally, so you only need to bring motor leads to the output terminals and line power to the input side. The 100 V DC coil connects to a control relay or PLC output — verify the coil's inrush current against your output card's rating. The IP20 enclosure means no live parts are exposed during normal operation, but the panel door should still be interlocked for safety.","metaTitle":"Schneider TeSys K LP2K1210KD3 Reversing Contactor, 12 A AC-3","metaDescription":"TeSys K reversing contactor LP2K1210KD3, 3P, AC-3 12 A at 440 V, 100 V DC coil. Obsolete — sourced to order against an RFQ. IP20, 57 mm deep.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4 AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/04d817427960ef105831976a257b58a6.pdf","sourceUrl":"https://www.se.com/in/en/product/LP2K1210KD3/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-100-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K1210KD3/alternatives.json"},"ai":{"faq":[{"question":"What replaces the LP2K1210KD3?","answer":"There is no official Schneider successor order code listed for this exact variant. A parametric substitute from the TeSys range would need matching coil voltage (100 V DC), AC-3 current rating (12 A at 440 V), and reversing configuration — but the mounting footprint and busbar arrangement must be verified for drop-in fit."},{"question":"What are the key ratings for this contactor?","answer":"AC-3 motor-switching current: 12 A at 440 V. Coil voltage: 100 V DC. Poles: 3 NO. Preassembled with reversing power busbar. IP20 finger-safe enclosure. Operating temperature: -25 to 50 °C."},{"question":"How do I source this obsolete part?","answer":"Since it is obsolete, we source it from surplus and broker channels against an RFQ. Submit a request with your quantity and target price; we will search sealed new-old-stock inventory and quote what is available."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K1210KD3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K1210KD3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}