{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K1210MP3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K1210MP3","canonicalUrl":"https://aoctrl.com/schneider/LP2K1210MP3","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K1210MP3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 12 A at 440 V, 1 NO auxiliary, 230 V DC coil.","salesMarkdown":"Rated AC-3 at 12 A up to 440 V, it handles reversing duty on small three-phase motors typical of conveyor drives, pump direction changes, or actuator open/close cycles. The 230 V DC coil suits systems with a DC control bus or where AC coil hum is undesirable. ## Mechanical fit and panel integration IP20 finger-safe protection (VDE 0106) means it is suited for enclosed control panels where accidental contact is prevented by the enclosure door. The preassembled reversing busbar saves the wireman from building a mechanical interlock with separate contactors, keeping the DIN-rail fill factor tight. The V-0 flame-retardance rating per UL 94 means the housing resists ignition in a fault scenario. Shock and vibration ratings follow IEC 60068-2-6 and IEC 60068-2-27 — the contactor holds closed under 15 Gn shocks on the Z axis, so it stays latched through machine vibration on a conveyor or press line.","metaTitle":"Schneider LP2K1210MP3 TeSys K Reversing Contactor, 12 A AC-3","metaDescription":"Schneider TeSys K reversing contactor LP2K1210MP3, 3P, AC-3 12 A at 440 V, 1 NO, 230 V DC coil. Obsolete — sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5da42edf7967ef2aa117d2eb83243c1a.pdf","sourceUrl":"https://www.se.com/mk/en/product/LP2K1210MP3/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-230-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP2K1210MP3/alternatives.json"},"ai":{"faq":[{"question":"What is the closest alternative to the LP2K1210MP3 in the TeSys family?","answer":"No official successor order code is listed in the lifecycle record. A direct pin-compatible replacement would need to match the 3-pole reversing contactor form factor, the 12 A AC-3 rating at 440 V, and the 230 V DC coil — but without a factory cross-reference, the fit must be verified against the existing panel wiring and mounting footprint."},{"question":"What are the key ratings for the LP2K1210MP3?","answer":"AC-3 motor switching rated 12 A at 440 V, with a 230 V DC coil. Three normally-open power poles, one normally-open auxiliary contact. The contactor is preassembled with a reversing power busbar for direction change without external interlocking."},{"question":"What compliance documentation is available for this part?","answer":"The contactor carries V-0 flame retardance per UL 94, IP20 finger-safe protection per VDE 0106, and shock/vibration testing per IEC 60068-2-27 and IEC 60068-2-6. The protective treatment conforms to IEC 60068 and DIN 50016. Operating altitude is 2000 m without derating."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K1210MP3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K1210MP3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}