{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K1210MPD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K1210MPD","canonicalUrl":"https://aoctrl.com/schneider/LP2K1210MPD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K1210MPD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 230 V DC coil, preassembled with reversing power busbar.","salesMarkdown":"The Schneider Electric LP2K1210MPD is a TeSys K reversing contactor — a 3-pole unit rated for AC-3 duty at 12 A up to 440 V, with a 230 V DC coil and one normally open auxiliary contact. It ships preassembled with the reversing power busbar, so you avoid the extra labour of wiring a mechanical interlock and busbar set between two separate contactors. That busbar is what makes it a reversing contactor rather than a pair of line contactors: it enforces the electrical and mechanical interlock that prevents both directions being energised simultaneously, which would be a phase-to-phase fault on a motor winding. The AC-3 rating of 12 A at 440 V governs motor switching — that is the utilisation category for starting and stopping squirrel-cage induction motors under load. The same contactor also carries AC-1 (resistive load) and AC-4 (plugging/inching) ratings, but the AC-3 figure is the one that decides whether this part holds the unit on the grid for a typical reversing drive. At 12 A AC-3, it covers motors up to roughly 5.5 kW at 400 V three-phase, provided the ambient stays within the -25 to 50 °C operating range. Above 50 °C you would need to derate, but the ledger does not carry the derating curve — that lives in the TeSys K application note. The 230 V DC coil is a point to watch: if your control voltage is 24 V DC or 110 V AC, this is not the coil variant you want. The coil draw at 230 V DC is modest, but verify your DC supply can deliver the inrush without droop. It belongs inside an enclosure rated for the environment. The mechanical robustness figures are solid: 15 Gn shock on the Z axis with contacts closed, 10 Gn with contacts opened, and vibration survival at 4 Gn closed, 2 Gn opened. That is enough for most industrial panels on a machine base, but if the contactor is mounted directly on a vibrating conveyor frame, you may want to check the resonant frequency against the 5–300 Hz sweep. The footprint is 90 mm wide by 58 mm high by 57 mm deep. The busbar and interlock are integrated.","metaTitle":"Schneider TeSys K LP2K1210MPD Reversing Contactor, 3P, 12 A","metaDescription":"TeSys K reversing contactor LP2K1210MPD, 3P, AC-3 <= 440 V 12 A, 1 NO, 230 V DC coil. Active production. IP20. Preassembled reversing busbar. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K1210MPD","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 230 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1 AC-3 AC-4","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a5ebe365995274f3e9acd878e3677010.pdf","sourceUrl":"https://www.se.com/in/en/product/LP2K1210MPD/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-230-v-dc-coil/"},"ai":{"faq":[{"question":"Does this contactor come with the reversing busbar pre-installed?","answer":"Yes, the device presentation is 'preassembled with reversing power busbar'. That means the mechanical interlock and the busbar that swaps two phases for reverse rotation are integrated into the unit — no separate interlock bracket or busbar kit to wire."},{"question":"What compliance certifications does the LP2K1210MPD carry?","answer":"It carries IP20 protection per VDE 0106, flame retardance V1 per UL 94, and compliance with NF F 16-101 and NF F 16-102 for railway fire-smoke-toxicity. The protective treatment meets IEC 60068 and DIN 50016 for environmental resistance."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K1210MPD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K1210MPD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}