{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K1210MUD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K1210MUD","canonicalUrl":"https://aoctrl.com/schneider/LP2K1210MUD","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K1210MUD","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K1210MUD, 3P, AC-3 <=440 V 12 A, 1 NO auxiliary, 240 V DC coil, preassembled with reversing power busbar.","salesMarkdown":"Rated AC-3 at 12 A up to 440 V, it handles reversing duty on small three-phase motors — conveyors, fans, pumps — where the load needs to change direction. The 240 V DC coil pulls in cleanly on a standard DC control supply; hold-in power is low enough that a PLC relay output can drive it directly. Footprint is 90 mm wide by 58 mm high by 57 mm deep — compact enough for a shallow enclosure or a crowded DIN rail. IP20 finger-safe terminals (VDE 0106) mean it can sit exposed in a control cabinet without an extra cover over the power connections. AC-1 rating covers resistive loads at the same current level. AC-4 rating handles plugging and inching duty where the contactor opens under full load. The single NO auxiliary contact (1 NO) is enough to seal in the coil or signal a PLC that the contactor has picked up; for more aux contacts, a TeSys K side-mount block can be added. Mechanical robustness is specified for 15 Gn shocks closed and 10 Gn open, plus 4 Gn vibration closed — rated for the vibration environment on a press or conveyor frame.","metaTitle":"Schneider TeSys K LP2K1210MUD reversing contactor, 3P, AC-3","metaDescription":"Active-production TeSys K reversing contactor, 3P, AC-3 <=440 V 12 A, 1 NO, 240 V DC coil. Preassembled reversing busbar. IP20. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K1210MUD","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 240 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-1 AC-4","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/11e55f20adb9406ef6df2507b9ed794a.pdf","sourceUrl":"https://www.se.com/ie/en/product/LP2K1210MUD/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-240-v-dc-coil/"},"ai":{"faq":[{"question":"What is the closest alternative within the TeSys K family?","answer":"Within the same TeSys K range, the LP2K series shares the same footprint and coil options. The LP2K1210MUD is the reversing version with a 240 V DC coil and 1 NO auxiliary. A non-reversing TeSys K contactor (LC1K series) with the same coil voltage would be the functional equivalent for forward-only duty, but lacks the integrated reversing busbar and mechanical interlock."},{"question":"What compliance documentation is available for this part?","answer":"The part carries V1 flame retardance per UL 94, and conforms to NF F 16-101 and NF F 16-102 for railway fire-smoke-toxicity. Protective treatment conforms to IEC 60068 and DIN 50016. IP20 per VDE 0106. Standard Schneider Electric declarations (CE, UKCA, RoHS, REACH) apply to the TeSys K series."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K1210MUD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K1210MUD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}