{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP2K1210ND3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP2K1210ND3","canonicalUrl":"https://aoctrl.com/schneider/LP2K1210ND3","factsUrl":"https://aoctrl.com/api/mcp/products/LP2K1210ND3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, LP2K1210ND3, 3P, AC-3 12 A at 440 V, 60 V DC coil, 1 NO auxiliary contact, IP20.","salesMarkdown":"## Reversing Contactor for Motor Control The 60 V DC coil with 1 NO auxiliary contact suits PLC or relay logic control circuits in control panels. The AC-3 rating (12 A at 440 V) governs motor switching — this is the duty that matters for inrush during starting. AC-1 (resistive) and AC-4 (plugging/inching) are also covered, but the AC-3 figure is the one to match against your motor FLA. The 60 V DC coil draws from a control supply common in marine and industrial panels; verify your DC bus voltage and polarity. IP20 finger-safe terminals (VDE 0106) mean it is intended for enclosure mounting, not exposed installation. ## Construction and Compliance The contactor carries V1 flame retardance per UL 94 and meets NF F 16-101/102 for rail applications. Protective treatment TC per IEC 60068 and DIN 50016 indicates resistance to corrosive atmospheres. Mechanical robustness is specified for shock and vibration: 15 Gn closed, 10 Gn open on Z axis per IEC 60068-2-27, and vibration up to 4 Gn closed, 2 Gn open at 5–300 Hz per IEC 60068-2-6. This makes it suitable for installations subject to transport or machinery vibration, including marine and mobile equipment. ## Panel Integration The preassembled reversing busbar saves panel wiring time and reduces error. Mounts on DIN rail or via screws (standard TeSys K base). IP20 allows close spacing in a control cabinet; plan for adequate ventilation if multiple contactors are ganged, as the 50 °C max ambient is the enclosure interior temperature.","metaTitle":"Schneider TeSys K LP2K1210ND3 Reversing Contactor, 12 A AC-3","metaDescription":"Schneider Electric TeSys K reversing contactor LP2K1210ND3, 3P, 12 A AC-3 at 440 V, 60 VDC coil, 1 NO aux. Active production. IP20. Order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","title":"LP2K1210ND3","Height":"58 mm","description":"TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 60 V DC coil","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP2K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-1 AC-4 AC-3","Contactor application":"Resistive load Motor control","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/93bfe168f4904eb21af7ae276bb08274.pdf","sourceUrl":"https://www.se.com/in/en/product/LP2K1210ND3/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-60-v-dc-coil/"},"ai":{"faq":[{"question":"What is the closest alternative to the LP2K1210ND3 in the TeSys K family?","answer":"Within the TeSys K range, the LP2K series shares the same physical footprint and busbar system. The key differentiator is the coil voltage: the LP2K1210ND3 uses a 60 V DC coil. For a 24 V DC coil, the equivalent is the LP2K1210BD3; for 110 V AC, the LP2K1210M7. All share the same 12 A AC-3 rating and 1 NO auxiliary contact."},{"question":"What is the depth of the LP2K1210ND3?","answer":"The depth is 57 mm. Overall dimensions are 90 mm wide × 58 mm high × 57 mm deep."},{"question":"What compliance documentation is available for the LP2K1210ND3?","answer":"The contactor carries V1 flame retardance per UL 94, meets NF F 16-101/102 for fire behaviour in rail vehicles, and has protective treatment TC per IEC 60068 and DIN 50016 for corrosive environments. IP20 per VDE 0106. Standard Schneider Electric declarations (RoHS, REACH) are available through the manufacturer's documentation portal."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP2K1210ND3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP2K1210ND3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}