{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP4K09015BW3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP4K09015BW3","canonicalUrl":"https://aoctrl.com/schneider/LP4K09015BW3","factsUrl":"https://aoctrl.com/api/mcp/products/LP4K09015BW3","rawCanonicalId":null},"summary":{"shortDescription":"Square D TeSys LP4K09015BW3, 3-pole contactor, 9 A AC-3, 1.8 W coil, 30 Mcycles mechanical, solder pin terminals.","salesMarkdown":"## TeSys LP4K09015BW3 – 9 A PCB-Mount Contactor Coil dissipation stays at 1.8 W, so heat buildup is minimal in tight enclosures. Mechanical life is rated at 30 Mcycles; electrical life hits 1.3 Mcycles at 9 A AC-3 and 0.16 Mcycles at 20 A AC-1. For low-level signalling, it can switch down to 5 mA at 17 V, which covers PLC outputs and pilot lamps without trouble. ## Mounting & Connections The LP4K09015BW3 uses solder pin terminals (0.035 mm diameter) intended for direct PCB mounting. IP2X protects against finger contact. One built-in NC auxiliary contact is included; no extra aux block needed for basic feedback. Coil suppression is integrated, so no external snubber required for standard PLC outputs.","metaTitle":"Square D LP4K09015BW3 TeSys Contactor, 9A AC-3","metaDescription":"Square D LP4K09015BW3 TeSys contactor, 3-pole, 9 A AC-3, 1.8 W coil, 30 Mcycles mechanical life, active production, sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"2.2 in (57 mm)","Range":"TeSys","Width":"1.8 in (45 mm)","Height":"2.3 in (58 mm)","Category":"US10I1222321","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4","Operating time":"10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing","Coil technology":"With integral suppression device","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.8 W","Mounting Support":"Printed circuit boards","Device short name":"LP4K","Inrush power in W":"1.8 W 68 °F (20 °C))","Poles description":"3P","Operating altitude":"6561.68 ft (2000 m) without derating","Utilisation category":"AC-3 AC-3e AC-1 AC-4","Contactor application":"Resistive load Motor control","Electrical durability":"1.3 Mcycles 9 A AC-3 1.3 Mcycles 9 A AC-3e 0.16 Mcycles 20 A AC-1 0.02 Mcycles 54 A AC-4 <= 440 V","Mechanical durability":"30 Mcycles","Nbr. of units in pkg.":"1","Maximum operating rate":"3600 cyc/h","Auxiliary contacts type":"Instantaneous 1 NC","Connections - terminals":"solder pins 0.001 in (0.035 mm))","IP degree of protection":"IP2X","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1","Minimum switching current":"5 mA for signalling circuit","Minimum switching voltage":"17 V for signalling circuit","Product or Component Type":"Contactor","Control circuit voltage limits":"Operational: 0.7...1.3 Uc (at Drop-out: >= 0.10 Uc (at <122 °F (50 °C))","Hold-in power consumption in W":"1.8 W 68 °F (20 °C)","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit Signalling circuit 10 MOhm for signalling circuit","Ambient Air Temperature for Storage":"-58...176 °F (-50...80 °C)","Ambient air temperature for operation":"-13...122 °F (-25...50 °C)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$118.09","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/49cef41e8d2a5649614b0f93523e3af9.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LP4K09015BW3/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings for this contactor?","answer":"It is a 3-pole contactor rated 9 A in AC-3 (motor) and 20 A in AC-1 (resistive). Coil power consumption is 1.8 W, mechanical life is 30 Mcycles, and electrical life at 9 A AC-3 is 1.3 Mcycles."},{"question":"What compliance standards does it meet?","answer":"It meets EN/IEC 60947-4-1, EN/IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, and GB/T 14048.4. Flammability is V1 per UL 94."},{"question":"What is the physical size of this contactor?","answer":"Depth 2.2 in (57 mm), width 1.8 in (45 mm), height 2.3 in (58 mm). It's designed for PCB mounting."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP4K09015BW3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP4K09015BW3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}