{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP5K090045JW3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP5K090045JW3","canonicalUrl":"https://aoctrl.com/schneider/LP5K090045JW3","factsUrl":"https://aoctrl.com/api/mcp/products/LP5K090045JW3","rawCanonicalId":null},"summary":{"shortDescription":"TeSys K changeover contactor, 4P, AC,1 <= 440 V 20 A, 12 V DC coil","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"2.2 in (57 mm)","Range":"TeSys","Width":"3.5 in (90 mm)","Height":"2.3 in (58 mm)","Category":"22322-CTR,K-LINE,DC,OPEN,REV","Standards":"IEC 60947 VDE 0660 NF C 63-110 BS 5424","Product name":"TeSys K","Operating time":"10...20 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing","Coil technology":"Built-in bidirectional peak limiting diode suppressor","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Heat dissipation":"1.8 W","Mounting Support":"Rail Plate","Average impedance":"3 mOhm - Ith 20 A 50 Hz for power circuit","Device short name":"LP5K","Inrush power in W":"1.8 W 68 °F (20 °C))","Interlocking type":"Mechanical","Poles description":"4P","Device Application":"Control","Operating altitude":"6561.68 ft (2000 m) without derating","Device presentation":"Preassembled with reversing power busbar","Control circuit type":"DC low consumption","Overvoltage category":"III","Protective treatment":"TC IEC 60068 TC DIN 50016","Utilisation category":"AC-1","Contactor application":"Resistive load","Electrical durability":"0.18 Mcycles 20 A AC-1 <= 440 V","Mechanical durability":"5 Mcycles","Mechanical robustness":"Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27 Vibrations contactor closed4 Gn, 5...300 Hz IEC 60068-2-6 Vibrations contactor opened2 Gn, 5...300 Hz IEC 60068-2-6 Shocks contactor opened, on X axis10 Gn for 11 ms IEC 60068-2-27 Shocks contactor opened, on Y axis6 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on X axis15 Gn for 11 ms IEC 60068-2-27 Shocks contactor closed, on Y axis10 Gn for 11 ms IEC 60068-2-27","Nbr. of units in pkg.":"1","Associated fuse rating":"25 A gG at 25 A aM for power circuit","Maximum operating rate":"3600 cyc/h","Connections - terminals":"solder pins 1.5 x 0.9 mm","IP degree of protection":"IP20 VDE 0106","Rated breaking capacity":"110 A at 415 V conforming to IEC 60947 110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947","Safety reliability level":"B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1","Product or Component Type":"Changeover contactor","Irms rated making capacity":"110 A AC for power circuit conforming to NF C 63-110 110 A AC for power circuit conforming to IEC 60947","[Uc] control circuit voltage":"12 V DC","[Ui] rated insulation voltage":"Power circuit 600 V UL 508 Power circuit 690 V IEC 60947-4-1 Power circuit 600 V CSA C22.2 No 14","Control circuit voltage limits":"Operational: 0.7...1.30 Uc (at Drop-out: 0.1...0.7 Uc (at <122 °F (50 °C))","Hold-in power consumption in W":"1.8 W 68 °F (20 °C)","Power Pole Contact Composition":"4 NO","[Ie] rated operational current":"20 A (at 16 A (at <158 °F (70 °C)) at 690 V AC AC-1 for power circuit","[Ue] rated operational voltage":"Power circuit 690 V AC 50/60 Hz","Ambient Air Temperature for Storage":"-58...176 °F (-50...80 °C)","Ambient Air Temperature for Operation":"-13...122 °F (-25...50 °C)","[Uimp] rated impulse withstand voltage":"8 kV","[Icw] rated short-time withstand current":"90 A 122 °F (50 °C) - 1 s for power circuit 85 A 122 °F (50 °C) - 5 s for power circuit 80 A 122 °F (50 °C) - 10 s for power circuit 60 A 122 °F (50 °C) - 30 s for power circuit 45 A 122 °F (50 °C) - 1 min for power circuit 40 A 122 °F (50 °C) - 3 min for power circuit 20 A 122 °F (50 °C) - >= 15 min for power circuit","[Ith] conventional free air thermal current":"20 A (at 122 °F (50 °C)) for power circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9932b5349b856c338f84231d8635cc0c.pdf","sourceUrl":"https://www.se.com/mk/en/product/LP5K090045JW3/tesys-k-changeover-contactor-4p-ac1-440-v-20-a-12-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP5K090045JW3/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP5K090045JW3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP5K090045JW3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}