{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LP5K1210JW3","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LP5K1210JW3","canonicalUrl":"https://aoctrl.com/schneider/LP5K1210JW3","factsUrl":"https://aoctrl.com/api/mcp/products/LP5K1210JW3","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys K reversing contactor, 3P, AC-3 <= 440 V 12 A, 1 NO, 12 V DC coil, IP20.","salesMarkdown":"The LP5K1210JW3 is a TeSys K reversing contactor from Schneider Electric, configured as 3-pole (3P) with three normally-open power poles and one normally-open auxiliary contact. It is rated for AC-3 duty at 12 A up to 440 V, making it suitable for switching small three-phase motor loads in reversing applications — think conveyors, hoists, or any direction-change circuit. The coil is 12 V DC, so it integrates directly into low-voltage DC control loops common in PLC-driven panels or battery-backed safety circuits. ## Integration Notes Dimensions are 90 mm wide × 58 mm high × 57 mm deep, fitting a standard DIN-rail footprint. The IP20 finger-safe terminals accept wire sizes typical for 12 A circuits (1.5 to 4 mm², depending on ferrule). Shock and vibration ratings (15 Gn closed, 4 Gn vibration) confirm it holds in on mobile or high-vibration equipment like crane panels or pump skids.","metaTitle":"Schneider Electric LP5K1210JW3 TeSys K Reversing Contactor,","metaDescription":"Obsolete TeSys K reversing contactor, 3P, AC-3 12 A at 440 V, 1 NO, 12 V DC coil. Sourced to order against RFQ via surplus channels.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":["Contactors"],"specifications":{"Depth":"57 mm","Range":"TeSys","Width":"90 mm","Height":"58 mm","Product name":"TeSys K","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94 Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102","Device short name":"LP5K","Poles description":"3P","Device application":"Control","Operating altitude":"2000 m without derating","Device presentation":"Preassembled with reversing power busbar","Protective treatment":"TC conforming to IEC 60068 TC conforming to DIN 50016","Utilisation category":"AC-3 AC-4 AC-1","Contactor application":"Motor control Resistive load","Mechanical robustness":"Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 Shocks contactor opened, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on X axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27","IP degree of protection":"IP20 conforming to VDE 0106","Product or component type":"Reversing contactor","Power Pole Contact Composition":"3 NO","[Ue] rated operational voltage":"Power circuit: 690 V AC 50/60 Hz Signalling circuit: 10 MOhm for signalling circuit","Ambient air temperature for storage":"-50...80 °C","Ambient air temperature for operation":"-25...50 °C"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/e19202a89061c3dfd19cfe061a5fa4dc.pdf","sourceUrl":"https://www.se.com/ie/en/product/LP5K1210JW3/tesys-k-reversing-contactor-3p-ac3-440-v-12-a-1-no-12-v-dc-coil/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LP5K1210JW3/alternatives.json"},"ai":{"faq":[{"question":"What are the key ratings of the LP5K1210JW3?","answer":"It is a 3-pole reversing contactor rated AC-3 at 12 A up to 440 V, with a 12 V DC coil and one normally-open auxiliary contact. It is part of the TeSys K series and carries IP20 protection."},{"question":"What is the operating temperature range for the LP5K1210JW3?","answer":"The ambient air temperature for operation is -25 to 50 °C, and for storage it is -50 to 80 °C."},{"question":"What compliance documentation does the LP5K1210JW3 have?","answer":"It meets UL 94 V1 flame retardance, NF F 16-101/102 for rail fire-smoke-toxicity, and IP20 per VDE 0106. It also conforms to IEC 60068 for shock and vibration, and IEC 60068 / DIN 50016 for protective treatment."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LP5K1210JW3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LP5K1210JW3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}