{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LR9D5369","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LR9D5369","canonicalUrl":"https://aoctrl.com/schneider/LR9D5369","factsUrl":"https://aoctrl.com/api/mcp/products/LR9D5369","rawCanonicalId":null},"summary":{"shortDescription":"Schneider Electric TeSys LR9D5369 electronic thermal overload relay, 90–150 A adjustment range, 24 V DC supply, Class 10 trip class, 1 NO + 1 NC auxiliary contacts.","salesMarkdown":"The LR9D5369: Electronic thermal overload relay for motor protection, part of the TeSys range. Adjusts from 90 to 150 A, Class 10 trip curve per IEC 60947-4-1, with phase failure sensitivity tripping in 4 seconds. Requires 24 V DC control supply. Auxiliary contacts 1 NO + 1 NC. Rated operational voltage 690 V AC, insulation voltage 1000 V. Compliant with UL 60947-4-1, CSA C22.2, IEC 60947-4-1. IP20 protection.","metaTitle":"TeSys LR9D5369 Electronic Overload Relay, 90-150 A, Class 10","metaDescription":"Schneider Electric TeSys LR9D5369 electronic thermal overload relay, 90-150 A adjustment, 24 V DC, Class 10 trip, phase failure detection. UL/IEC/CSA. Active production, sourced to","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Obsolete","categoryPath":[],"specifications":{"Depth":"4.9 in (125 mm)","Range":"TeSys","Width":"4.5 in (115 mm)","Height":"4.6 in (118 mm)","Category":"US10I1222347","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5","Control type":"Red push-button stop Blue push-button reset","Network type":"AC","Product name":"TeSys LRD TeSys Deca","lifecycle_stage":"current","Mounting support":"Under contactor Rail","Device short name":"LR9D","Network Frequency":"50-60 Hz","Relay application":"Motor protection","Tightening torque":"Alarm circuit 3.98 lbf.in (0.45 N.m) screw clamp terminals Power circuit 159.3 lbf.in (18 N.m) bars M8 Control circuit 10.6 lbf.in (1.2 N.m) screw clamp terminals","Climatic withstand":"IACS E10","Operating altitude":"<= 6561.68 ft (2000 m) without derating","Tripping threshold":"1.05 +/- 0.06 In alarm IEC 60947-4-1 1.12 +/- 0.06 In de-energisation IEC 60947-4-1","Dielectric strength":"1.89 kV 50 Hz IEC 60947-1","Signalling function":"Alarm","Maximum voltage drop":"<2.5 V closed state","Mechanical robustness":"Vibrations2 Gn, 5...300 Hz IEC 60068-2-6 Shocks13 Gn for 11 ms IEC 60068-2-7","Nbr. of units in pkg.":"1","Supply voltage limits":"17...32 V","Associated fuse rating":"4 A gG for signalling circuit 4 A BS for signalling circuit","Thermal overload class":"Class 10 IEC 60947-4-1","Connections - terminals":"Power circuit bars Control circuit screw clamp terminals 1 0.0008...0.002 in² (0.5...1.5 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.0008...0.002 in² (0.5...1.5 mm²) flexible without cable end Alarm circuit screw clamp terminals 1 0.0008...0.002 in² (0.5...1.5 mm²) flexible without cable end","IP degree of protection":"IP20 conforming to IEC 60529","Switching capacity in mA":"0...150 mA","Temperature compensation":"-4...140 °F (-20...60 °C)","Phase failure sensitivity":"Tripping in 4 s +/- 20 % IEC 60947-4-1","Product or Component Type":"Electronic thermal overload relay","[Us] rated supply voltage":"24 V DC","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"Power circuit 1000 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL","[Ue] rated operational voltage":"690 V AC 0...400 Hz power circuit IEC 60947-4-1","Ambient Air Temperature for Storage":"-76...158 °F (-60...70 °C)","Thermal protection adjustment range":"90...150 A","Ambient air temperature for operation":"-4...140 °F (-20...60 °C) without derating IEC 60947-4-1","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-1","[Ith] conventional free air thermal current":"5 A signalling circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$135.89","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/24b7802fbc825d715e1c7a1faec35f6b.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LR9D5369/alternatives.json"},"ai":{"faq":[{"question":"What motor protection standards does this relay meet?","answer":"It complies with IEC 60947-4-1, UL 60947-4-1, CSA C22.2 No 60947-4-1, and GB/T 14048.4 for thermal overload and phase failure protection."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LR9D5369","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LR9D5369 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}