{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LRD4365","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LRD4365","canonicalUrl":"https://aoctrl.com/schneider/LRD4365","factsUrl":"https://aoctrl.com/api/mcp/products/LRD4365","rawCanonicalId":null},"summary":{"shortDescription":"Thermal Overload Relay, TeSys Deca, 80 - 104A, Class 10A, EVERLINK|Thermal Overload Relay, TeSys Deca, 80 - 104 Amp, Class 10A, EVERLINK","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"5.2 in (132 mm)","Range":"TeSys","Category":"US10I1222347","Standards":"EN/IEC 60947-4-1 EN/IEC 60947-5-1 UL 60947-4-1 UL 60947-5-1 CSA C22.2 No 60947-4-1 CSA C22.2 No 60947-5-1 GB/T 14048.4 GB/T 14048.5 EN 50495","Control type":"Red push-button stop Blue push-button reset","Network type":"AC DC","Product name":"TeSys LRD TeSys Deca","lifecycle_stage":"current","Flame retardance":"V1 conforming to UL 94","Mounting support":"Plate, with specific accessories Rail, with specific accessories Under contactor","Device short name":"LRD","Network Frequency":"0...400 Hz","Relay application":"Motor protection","Tightening torque":"Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals Power circuit 79.7 lbf.in (9 N.m) screw clamp terminals","Climatic withstand":"IACS E10","Tripping threshold":"1.14 +/- 0.06 Ir IEC 60947-4-1","Dielectric strength":"2.2 kV 50 Hz IEC 60947-1","Permissible current":"0.06 A 440 V DC-13 signalling circuit 0.12 A 600 V AC-15 signalling circuit","Mechanical robustness":"Vibrations6 Gn IEC 60068-2-6 Shocks15 Gn for 11 ms IEC 60068-2-7","Nbr. of units in pkg.":"1","Associated fuse rating":"4 A gG for signalling circuit 4 A BS for signalling circuit","Thermal overload class":"Class 10A IEC 60947-4-1","Connections - terminals":"Power circuit screw clamp terminals 1 0.006...0.05 in² (4...35 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) flexible without cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) flexible with cable end Control circuit screw clamp terminals 2 0.002...0.004 in² (1...2.5 mm²) solid without cable end Power circuit screw clamp terminals 1 0.006...0.08 in² (4...50 mm²) flexible without cable end Power circuit screw clamp terminals 1 0.006...0.08 in² (4...50 mm²) solid without cable end","IP degree of protection":"IP20 conforming to IEC 60529","Temperature compensation":"-4...140 °F (-20...60 °C)","Phase failure sensitivity":"Tripping current 130 % of Ir on two phase, the last one at 0","Product or Component Type":"Differential thermal overload relay","Auxiliary contact composition":"1 NO + 1 NC","[Ui] rated insulation voltage":"Power circuit 1000 V IEC 60947-4-1 Power circuit 600 V CSA Power circuit 600 V UL","[Ue] rated operational voltage":"1000 V AC 0...400 Hz power circuit IEC 60947-4-1","Ambient Air Temperature for Storage":"-76...158 °F (-60...70 °C)","Thermal protection adjustment range":"80...104 A","Ambient air temperature for operation":"-4...140 °F (-20...60 °C) without derating IEC 60947-4-1","[Uimp] rated impulse withstand voltage":"6 kV IEC 60947-1","[Ith] conventional free air thermal current":"5 A signalling circuit"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$99.09","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/4b92cb1042926eed96d5fa3f2e687cff.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LRD4365/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LRD4365","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LRD4365 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}