{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LTMEV40FM","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LTMEV40FM","canonicalUrl":"https://aoctrl.com/schneider/LTMEV40FM","factsUrl":"https://aoctrl.com/api/mcp/products/LTMEV40FM","rawCanonicalId":null},"summary":{"shortDescription":"Extension module, TeSys T, 4 inputs, 100 to 240VAC, for LTMR controller|Extension module, TeSys T, 4 inputs, 100 to 240VAC, for LTMR controller","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"4.8 in (120.7 mm)","Range":"TeSys","Width":"1.8 in (45 mm)","Height":"2.4 in (61 mm)","Supply":"Via the controller","Category":"US10I1222338","Standards":"CSA C22.2 No 14 IACS E10 IEC 60947-4-1 UL 508 EN 60947-4-1","Product name":"TeSys T","Input current":"3.1 mA 100 V 7.5 mA 240 V","Metering type":"Imbalance voltage Active power P, P1, P2, P3 Calculated active and reactive energy (+/- W.h, +/- VAR.h) Voltage U21, U32, U13, V1, V2, V3 Reactive power Q, Q1, Q2, Q3 Frequency Power factor","Product Weight":"0.46 lb(US) (0.21 kg)","Fire resistance":"1202 °F (650 °C) EN/IEC 60695-2-12 1760 °F (960 °C) UL 94","lifecycle_stage":"unknown","Connection pitch":"0.20 in (5.08 mm)","Pollution degree":"3","Device short name":"LTME","Tightening torque":"Control circuit: 4.4...5.3 lbf.in (0.5...0.6 N.m) flat screwdriver 0.1 in (3 mm)","Compatibility code":"LTME","Device Application":"Equipment monitoring and control","Logic input number":"4","Operating altitude":"<= 6561.68 ft (2000 m) without derating","Measurement accuracy":"1 % voltage 100...830 V) 3 % power factor 5 % active and reactive power","Overvoltage category":"III","Protective treatment":"12 x 24 hour cycles EN/IEC 60068-2-30 48 h EN/IEC 60070-2-11 TH EN/IEC 60068","Mechanical robustness":"Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27 Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6","Nbr. of units in pkg.":"1","Maximum Operating Rate":"1800 cyc/h","Connections - terminals":"Control circuit connector 1 0.0004...0.004 in² (0.25...2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.0003...0.004 in² (0.2...2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004...0.004 in² (0.25...2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0003...0.004 in² (0.2...2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0008...0.002 in² (0.5...1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1 mm²) AWG 24...AWG 14)solid without cable end","IP Degree of Protection":"IP20","Product or Component Type":"Extension module","Current state 0 guaranteed":"Logic input 0...40 V 2...15 mA 25 ms","Current state 1 guaranteed":"Logic input 79...264 V <= 15 mA 25 ms","Contacts type and composition":"Without","Electromagnetic compatibility":"Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Voltage inputs: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Voltage inputs: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5","[Ui] rated insulation voltage":"690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508","Maximum Output Switching Frequency":"2 Hz","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"4 kV supply, inputs and outputs EN/IEC 60947-4-1 6 kV current or voltage measurement circuit EN/IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$128.27 – $369.57","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad1a8adc18d1fba7efd2b2a9b61f15ec.pdf","sourceUrl":null,"alternativesUrl":"https://aoctrl.com/api/mcp/products/LTMEV40FM/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LTMEV40FM","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LTMEV40FM when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}