{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"LTMR08CBD","brand":"Schneider Electric","brandSlug":"schneider","productSlug":"LTMR08CBD","canonicalUrl":"https://aoctrl.com/schneider/LTMR08CBD","factsUrl":"https://aoctrl.com/api/mcp/products/LTMR08CBD","rawCanonicalId":null},"summary":{"shortDescription":"Motor Management, TeSys T, motor controller, CANopen, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 24 VDC","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"4.8 in (122.5 mm)","Range":"TeSys","Width":"3.6 in (91 mm)","Height":"2.4 in (61 mm)","Bus type":"CANopen ISO 1198 1...127 10...1000 kbit/s, SUB-D 9 4 twisted shielded pairs cable CANopen ISO 1198 1...127 10...1000 kbit/s, terminal block 4 twisted shielded pairs cable","Category":"US10I1222338","Standards":"EN 60947-4-1 CSA C22.2 No 14 IEC 60947-4-1 UL 508 IACS E10","Load current":"5 A 250 V AC logic output 5 A 30 V DC logic output","Product name":"TeSys T","Web services":"Web server","Input current":"7 mA","Metering type":"Average current Iavg Phase current I1, I2, I3 RMS Temperature Earth-fault current Imbalance current","Product Weight":"1.17 lb(US) (0.53 kg)","Fire resistance":"1202 °F (650 °C) EN/IEC 60695-2-12 1760 °F (960 °C) UL 94","Protection Type":"Overload (long time) Phase failure Load fluctuation Phase imbalance Reverse polarity protection Thermal protection Thermal overload protection Earth-leakage protection Power factor variation Overload Locked rotor","lifecycle_stage":"unknown","Connection pitch":"0.20 in (5.08 mm)","Pollution degree":"3","Device short name":"LTMR","Permissible power":"480 VA AC-15), Ie = 2 A, 500000 cycles output) 30 W DC-13), Ie = 1.25 A, 500000 cycles output)","Tightening torque":"Control circuit: 4.4...5.3 lbf.in (0.5...0.6 N.m) flat screwdriver 0.1 in (3 mm)","Compatibility code":"LTMR","Device Application":"Equipment monitoring and control","Logic input number":"6","Operating altitude":"<= 6561.68 ft (2000 m) without derating","Current Consumption":"56...127 mA","Measurement current":"0.4...8 A","Measurement accuracy":"5...15 % earth fault current internal measurement 1 % voltage 100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 Temperature 1 % current 5 % active and reactive power","Overvoltage category":"III","Protective treatment":"12 x 24 hour cycles EN/IEC 60068-2-30 48 h EN/IEC 60070-2-11 TH EN/IEC 60068","Mechanical robustness":"Vibrations mounted on symmetrical rail1 Gn, 5...300 Hz EN/IEC 60068-2-6 Vibrations plate mounted4 Gn, 5...300 Hz EN/IEC 60068-2-6 Shocks half sine wave acceleration15 Gn for 11 ms EN/IEC 60068-2-27","Nbr. of units in pkg.":"1","Supply voltage limits":"20.4...26.24 V DC","Associated fuse rating":"4 A gG output 0.5 A gG control circuit","Maximum Operating Rate":"1800 cyc/h","Connections - terminals":"Control circuit connector 1 0.0004...0.004 in² (0.25...2.5 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 1 0.0003...0.004 in² (0.2...2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0004...0.004 in² (0.25...2.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 1 0.0003...0.004 in² (0.2...2.5 mm²) AWG 24...AWG 14)solid without cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1 mm²) AWG 24...AWG 14)flexible with cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0008...0.002 in² (0.5...1.5 mm²) AWG 24...AWG 14)flexible without cable end Control circuit connector 2 0.0003...0.002 in² (0.2...1 mm²) AWG 24...AWG 14)solid without cable end","IP Degree of Protection":"IP20","Short-circuit withstand":"100 kA conforming to EN/IEC 60947-4-1","Product or Component Type":"Motor controller","[Us] rated supply voltage":"24 V DC","Current state 0 guaranteed":"Logic input < 5 V <= 15 mA 5 ms","Current state 1 guaranteed":"Logic input < 15 V 2...15 mA 15 ms","Communication Port Protocol":"CANopen","Contacts type and composition":"1 NO + 1 NC fault signal 3 NO","Electromagnetic compatibility":"Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5","[Ui] rated insulation voltage":"690 V EN/IEC 60947-1 690 V CSA C22.2 No 14 690 V UL 508","Maximum Output Switching Frequency":"2 Hz","Network and machine diagnosis type":"Trip context information Remaining operating time before overload tripping Starting current and time Event recording Motor control command recording Running hours counter/operating time Waiting time after overload tripping Trip history information Phase fault and earth fault trip counters Fault recording","Ambient Air Temperature for Storage":"-40...176 °F (-40...80 °C)","Ambient air temperature for operation":"-4...140 °F (-20...60 °C)","[Uimp] rated impulse withstand voltage":"6 kV current or voltage measurement circuit EN/IEC 60947-4-1 0.8 kV communication circuit EN/IEC 60947-4-1 0.8 kV supply, inputs and outputs EN/IEC 60947-4-1"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$742.50 – $1,153.98","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ade231e9ff517a3a602090f3439052d6.pdf","sourceUrl":"https://www.se.com/ie/en/product/LTMR08CBD/motor-management-tesys-t-motor-controller-canopen-6-logic-inputs-3-relay-logic-outputs-0-4-to-8a-24-vdc/","alternativesUrl":"https://aoctrl.com/api/mcp/products/LTMR08CBD/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/schneider/LTMR08CBD","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/schneider/LTMR08CBD when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:21:01.794Z","lastPublished":"2026-09-02T08:21:01.794Z","indexable":true}}